NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 03/25/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 BEAVER VALLEY 1 4501 000 03/19 03/28 MODE 5 - COLD SHUTDOWN * MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 BEAVER VALLEY 2 4501 000 03/19 03/30 MODE 5 - COLD SHUTDOWN * MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 1 4502 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 2 4502 000 03/15 05/01 MODE 6 - REFUELING * REFUELING OUTAGE - PLAN TO LIFT REACTOR HEAD TONIGHT -------------------------------------------------------------------------------- 1 FITZPATRICK 1 4503 090 INCREASING POWER * FOLLOWING LOAD REDUCTION TO 75% FOR CONTROL ROD SWAP -------------------------------------------------------------------------------- 1 GINNA 1 4504 100 -------------------------------------------------------------------------------- 1 HOPE CREEK 1 4506 100 -------------------------------------------------------------------------------- 1 INDIAN POINT 2 4507 100 LESS THAN 2 GPD #23 STEAM GENERATOR TUBE LEAK (TECH SPEC LIMIT IS 432 GPD) -------------------------------------------------------------------------------- 1 INDIAN POINT 3 4508 100 -------------------------------------------------------------------------------- 1 LIMERICK 1 4509 100 -------------------------------------------------------------------------------- 1 LIMERICK 2 4509 100 -------------------------------------------------------------------------------- 1 MAINE YANKEE 1 4510 000 12/96 UNK MODE 6 - REFUELING REFUELING OUTAGE - FUEL IN CORE -------------------------------------------------------------------------------- 1 MILLSTONE 1 4511 000 11/95 UNK COND 5 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 MILLSTONE 2 4512 000 02/96 UNK MODE 6 - REFUELING MAINTENANCE OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 MILLSTONE 3 4513 000 03/96 UNK MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 NINE MILE POINT 1 4514 000 03/03 04/07 COND 5 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 03/25/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 NINE MILE POINT 2 4514 100 -------------------------------------------------------------------------------- 1 OYSTER CREEK 1 4515 100 -------------------------------------------------------------------------------- 1 PEACH BOTTOM 2 4516 100 -------------------------------------------------------------------------------- 1 PEACH BOTTOM 3 4516 100 -------------------------------------------------------------------------------- 1 PILGRIM 1 4517 000 02/14 04/22 COND 5 - REFUELING * REFUELING OUTAGE - PREPARING FOR VESSEL HYDRO - PLAN TO REPLACE MAIN TRANSFORMER -------------------------------------------------------------------------------- 1 SALEM 1 4518 000 05/95 07/01 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 SALEM 2 4518 000 06/95 04/01 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 1 SEABROOK 1 4519 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 1 4520 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 2 4520 000 03/15 04/12 COND 5 - REFUELING * REFUELING OUTAGE - COMPLETED OFFLOAD OF FUEL BUNDLES AROUND CONTROL ROD DRIVE ASSEMBLIES SCHEDULED FOR REPLACEMENT -------------------------------------------------------------------------------- 1 THREE MILE ISLAND 1 4521 100 -------------------------------------------------------------------------------- 1 VERMONT YANKEE 1 4522 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 03/25/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 BROWNS FERRY 1 4525 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BROWNS FERRY 2 4525 100 -------------------------------------------------------------------------------- 2 BROWNS FERRY 3 4525 100 -------------------------------------------------------------------------------- 2 BRUNSWICK 1 4526 095 ADMIN LIMIT OF 95% PENDING RESOLUTION OF POWER UPRATE ISSUES -------------------------------------------------------------------------------- 2 BRUNSWICK 2 4526 100 -------------------------------------------------------------------------------- 2 CATAWBA 1 4527 100 -------------------------------------------------------------------------------- 2 CATAWBA 2 4527 000 03/21 04/29 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 2 CRYSTAL RIVER 3 4528 000 09/96 12/31 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 2 FARLEY 1 4529 000 03/15 05/09 MODE 6 - REFUELING * REFUELING OUTAGE - DEFUELED - UNIT IN MIDLOOP - PLAN TO BE IN MIDLOOP UNTIL 03/29/97 -------------------------------------------------------------------------------- 2 FARLEY 2 4529 100 -------------------------------------------------------------------------------- 2 HARRIS 1 4531 100 -------------------------------------------------------------------------------- 2 HATCH 1 4532 100 -------------------------------------------------------------------------------- 2 HATCH 2 4532 000 03/15 04/18 COND 5 - REFUELING REFUELING OUTAGE - 35 FUEL BUNDLES OFFLOADED - FUEL SHUFFLE PENDING -------------------------------------------------------------------------------- 2 MCGUIRE 1 4533 000 02/14 05/23 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED - REPLACING STEAM GENERATORS -------------------------------------------------------------------------------- 2 MCGUIRE 2 4533 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 1 4534 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 2 4534 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 03/25/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 OCONEE 1 4535 100 MAY SHUT DOWN ON * 03/28/97 TO REPAIR 1A1 REACTOR COOLANT PUMP MOTOR BEARINGS -------------------------------------------------------------------------------- 2 OCONEE 2 4535 100 -------------------------------------------------------------------------------- 2 OCONEE 3 4535 097 INCREASING POWER * FOLLOWING INTEGRATED CONTROL SYSTEM TUNING AT 90% POWER -------------------------------------------------------------------------------- 2 ROBINSON 2 4536 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 1 4537 000 03/22 05/09 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 2 SEQUOYAH 2 4537 100 -------------------------------------------------------------------------------- 2 ST LUCIE 1 4538 100 -------------------------------------------------------------------------------- 2 ST LUCIE 2 4538 100 -------------------------------------------------------------------------------- 2 SUMMER 1 4539 100 -------------------------------------------------------------------------------- 2 SURRY 1 4540 000 03/06 04/12 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 2 SURRY 2 4540 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 3 4541 000 03/02 04/03 MODE 6 - REFUELING * REFUELING OUTAGE - FUEL RELOAD COMPLETE - VESSEL HEAD ON - LOWER CAVITY DRAIN DOWN IN PROGRESS -------------------------------------------------------------------------------- 2 TURKEY POINT 4 4541 100 -------------------------------------------------------------------------------- 2 VOGTLE 1 4542 100 -------------------------------------------------------------------------------- 2 VOGTLE 2 4542 100 -------------------------------------------------------------------------------- 2 WATTS BAR 1 4543 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 03/25/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 BIG ROCK POINT 1 4544 000 03/02 04/01 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 BRAIDWOOD 1 4545 100 -------------------------------------------------------------------------------- 3 BRAIDWOOD 2 4545 100 -------------------------------------------------------------------------------- 3 BYRON 1 4546 097 FULL POWER = 97% -------------------------------------------------------------------------------- 3 BYRON 2 4546 100 -------------------------------------------------------------------------------- 3 CLINTON 1 4548 000 09/96 04/18 COND 4 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 3 COOK 1 4549 000 02/28 04/14 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 3 COOK 2 4549 100 -------------------------------------------------------------------------------- 3 DAVIS BESSE 1 4550 100 -------------------------------------------------------------------------------- 3 DRESDEN 2 4551 070 HOLDING POWER AT THIS * LEVEL TO REPAIR A FEEDWATER HEATER STEAM LEAK -------------------------------------------------------------------------------- 3 DRESDEN 3 4551 063 COASTDOWN TO REFUELING * OUTAGE WHICH IS SCHEDULED TO BEGIN ON 03/29/97 -------------------------------------------------------------------------------- 3 DUANE ARNOLD 1 4552 100 -------------------------------------------------------------------------------- 3 FERMI 2 4553 000 01/17 04/05 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 KEWAUNEE 1 4554 000 09/96 06/01 MODE 6 - REFUELING REFUELING OUTAGE - FUEL RELOAD COMPLETE -------------------------------------------------------------------------------- 3 LASALLE 1 4555 000 09/96 04/12 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE - UNUSUAL EVENT DECLARED ON 03/11/97 DUE TO HIGH LAKE LEVEL (REFER TO EVENT #31934) - LEVEL DECREASING SLOWLY - RAIN IN FORECAST - EXPECT TO TERMINATE UNUSUAL EVENT ON 03/28/97 NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 03/25/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 LASALLE 2 4555 000 09/96 UNK COND 5 - REFUELING REFUELING OUTAGE - DEFUELED - UNUSUAL EVENT DECLARED ON 03/11/97 DUE TO HIGH LAKE LEVEL (REFER TO EVENT #31934) - LEVEL DECREASING SLOWLY - RAIN IN FORECAST - EXPECT TO TERMINATE UNUSUAL EVENT ON 03/28/97 -------------------------------------------------------------------------------- 3 MONTICELLO 1 4556 100 -------------------------------------------------------------------------------- 3 PALISADES 1 4557 100 -------------------------------------------------------------------------------- 3 PERRY 1 4558 100 -------------------------------------------------------------------------------- 3 POINT BEACH 1 4559 000 02/18 06/30 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 POINT BEACH 2 4559 000 10/96 04/12 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 1 4560 100 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 2 4560 000 01/24 03/27 MODE 3 - HOT STANDBY * EXITING REFUELING OUTAGE -------------------------------------------------------------------------------- 3 QUAD CITIES 1 4561 000 03/21 03/27 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE FOR FEEDWATER HEATER LEVEL CONTROL REPAIRS -------------------------------------------------------------------------------- 3 QUAD CITIES 2 4561 000 02/28 05/01 COND 5 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 3 ZION 1 4562 000 02/21 UNK MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 ZION 2 4562 000 09/96 UNK MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 03/25/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 ARKANSAS NUCLEAR 1 4563 100 -------------------------------------------------------------------------------- 4 ARKANSAS NUCLEAR 2 4563 097 FULL POWER = 97% -------------------------------------------------------------------------------- 4 CALLAWAY 1 4564 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 1 4565 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 2 4565 100 -------------------------------------------------------------------------------- 4 COOPER 1 4566 092 COASTDOWN TO REFUELING * OUTAGE WHICH IS SCHEDULED TO BEGIN ON 03/28/97 -------------------------------------------------------------------------------- 4 DIABLO CANYON 1 4567 100 -------------------------------------------------------------------------------- 4 DIABLO CANYON 2 4567 100 -------------------------------------------------------------------------------- 4 FT CALHOUN 1 4568 100 -------------------------------------------------------------------------------- 4 GRAND GULF 1 4569 100 * -------------------------------------------------------------------------------- 4 PALO VERDE 1 4570 062 HOLDING POWER AT THIS * LEVEL TO REPAIR A LOW PRESSURE FEEDWATER HEATER TUBE LEAK -------------------------------------------------------------------------------- 4 PALO VERDE 2 4570 100 -------------------------------------------------------------------------------- 4 PALO VERDE 3 4570 000 02/22 04/03 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 4 RIVER BEND 1 4571 100 -------------------------------------------------------------------------------- 4 SAN ONOFRE 2 4572 000 11/96 04/02 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE - STARTUP POSTPONED DUE TO DISCOVERY OF ANOTHER STEAM GENERATOR MANWAY LEAK - PLAN TO RE-ENTER MODE 4 ON 03/27/97 FOLLOWING DRAINDOWN AND REPAIR -------------------------------------------------------------------------------- 4 SAN ONOFRE 3 4572 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 1 4573 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 2 4573 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 03/25/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 WASHINGTON NUCLEAR 2 4574 057 LOAD FOLLOWING UNTIL * 03/26/97 PER LOAD DISPATCHER - PLAN TO INCREASE POWER TO 90% ON 03/26/97 TO PERFORM DIGITAL FEEDWATER POST- MAINTENANCE TESTING -------------------------------------------------------------------------------- 4 WATERFORD 3 4575 100 -------------------------------------------------------------------------------- 4 WOLF CREEK 1 4576 100 -------------------------------------------------------------------------------- * - REASON OR COMMENT HAS BEEN CHANGED IN PAST 24 HOURS # - NUMBER OF REACTOR SCRAMS WITHIN PAST 24 HOURS NOTE - REACTOR STATUS DATA COLLECTED BETWEEN 4 A.M. AND 8 A.M. EACH DAY. ALL TIMES ARE BASED ON EASTERN TIMES (ET).