NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 07/03/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 BEAVER VALLEY 1 4501 000 06/27 UNK MODE 3 - HOT STANDBY * MAINTENANCE OUTAGE - TECHNICAL SPECIFICATION REQUIRED SHUTDOWN TO MODE 5 INITIATED DUE TO THE UNISOLATION OF AN RHR SAMPLE SYSTEM PIPING PENETRATION FOR REQUIRED CHEMISTRY SAMPLING (REFER TO EVENT #32583) -------------------------------------------------------------------------------- 1 BEAVER VALLEY 2 4501 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 1 4502 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 2 4502 100 -------------------------------------------------------------------------------- 1 FITZPATRICK 1 4503 100 -------------------------------------------------------------------------------- 1 GINNA 1 4504 100 -------------------------------------------------------------------------------- 1 HOPE CREEK 1 4506 097 COASTDOWN TO REFUELING * OUTAGE -------------------------------------------------------------------------------- 1 INDIAN POINT 2 4507 000 05/01 07/04 MODE 4 - HOT SHUTDOWN EXITING REFUELING OUTAGE -------------------------------------------------------------------------------- 1 INDIAN POINT 3 4508 000 05/14 08/03 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 LIMERICK 1 4509 100 -------------------------------------------------------------------------------- 1 LIMERICK 2 4509 100 -------------------------------------------------------------------------------- 1 MAINE YANKEE 1 4510 000 12/96 UNK MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 MILLSTONE 1 4511 000 11/95 UNK COND 5 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 MILLSTONE 2 4512 000 02/96 UNK MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 MILLSTONE 3 4513 000 03/96 UNK MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 NINE MILE POINT 1 4514 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 07/03/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 NINE MILE POINT 2 4514 095 MOISTURE SEPARATOR REHEATER OUT OF SERVICE -------------------------------------------------------------------------------- 1 OYSTER CREEK 1 4515 100 -------------------------------------------------------------------------------- 1 PEACH BOTTOM 2 4516 100 -------------------------------------------------------------------------------- 1 PEACH BOTTOM 3 4516 094 COASTDOWN TO REFUELING OUTAGE -------------------------------------------------------------------------------- 1 PILGRIM 1 4517 100 -------------------------------------------------------------------------------- 1 SALEM 1 4518 000 05/95 11/15 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 SALEM 2 4518 000 06/95 07/11 MODE 4 - HOT SHUTDOWN EXITING REFUELING OUTAGE -------------------------------------------------------------------------------- 1 SEABROOK 1 4519 100 * -------------------------------------------------------------------------------- 1 SUSQUEHANNA 1 4520 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 2 4520 100 -------------------------------------------------------------------------------- 1 THREE MILE ISLAND 1 4521 100 -------------------------------------------------------------------------------- 1 VERMONT YANKEE 1 4522 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 07/03/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 BROWNS FERRY 1 4525 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BROWNS FERRY 2 4525 100 -------------------------------------------------------------------------------- 2 BROWNS FERRY 3 4525 100 -------------------------------------------------------------------------------- 2 BRUNSWICK 1 4526 097 PLAN TO PERFORM ROD IMPROVEMENTS OVER HOLIDAY WEEKEND -------------------------------------------------------------------------------- 2 BRUNSWICK 2 4526 099 PLAN TO PERFORM ROD IMPROVEMENTS OVER HOLIDAY WEEKEND -------------------------------------------------------------------------------- 2 CATAWBA 1 4527 100 -------------------------------------------------------------------------------- 2 CATAWBA 2 4527 065 INCREASING POWER * FOLLOWING A LOAD REDUCTION TO 50% DUE TO A MAIN GENERATOR BREAKER FAILURE AT 2100 ON 07/02/97 -------------------------------------------------------------------------------- 2 CRYSTAL RIVER 3 4528 000 09/96 12/31 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 2 FARLEY 1 4529 100 -------------------------------------------------------------------------------- 2 FARLEY 2 4529 100 -------------------------------------------------------------------------------- 2 HARRIS 1 4531 100 -------------------------------------------------------------------------------- 2 HATCH 1 4532 100 -------------------------------------------------------------------------------- 2 HATCH 2 4532 100 -------------------------------------------------------------------------------- 2 MCGUIRE 1 4533 100 * -------------------------------------------------------------------------------- 2 MCGUIRE 2 4533 098 POWER LIMITED BECAUSE TURBINE THROTTLE VALVES ARE OPENED TO PROCEDURAL LIMIT -------------------------------------------------------------------------------- 2 NORTH ANNA 1 4534 097 POWER LIMITED DUE TO A * TURBINE GOVERNOR VALVE VIBRATION PROBLEM -------------------------------------------------------------------------------- 2 NORTH ANNA 2 4534 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 07/03/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 OCONEE 1 4535 000 06/13 07/03 MODE 3 - HOT STANDBY * EXITING MAINTENANCE OUTAGE - CURRENTLY IN THE PROCESS OF GOING CRITICAL - PLAN TO PLACE THE UNIT ON LINE TODAY -------------------------------------------------------------------------------- 2 OCONEE 2 4535 100 -------------------------------------------------------------------------------- 2 OCONEE 3 4535 013 MAIN TURBINE OFF LINE FOR MAINTENANCE - REPLACING MAIN GENERATOR HYDROGEN SEALS (FOUND A COCKED SEAL) -------------------------------------------------------------------------------- 2 ROBINSON 2 4536 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 1 4537 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 2 4537 100 -------------------------------------------------------------------------------- 2 ST LUCIE 1 4538 100 -------------------------------------------------------------------------------- 2 ST LUCIE 2 4538 100 -------------------------------------------------------------------------------- 2 SUMMER 1 4539 100 -------------------------------------------------------------------------------- 2 SURRY 1 4540 100 -------------------------------------------------------------------------------- 2 SURRY 2 4540 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 3 4541 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 4 4541 100 -------------------------------------------------------------------------------- 2 VOGTLE 1 4542 100 -------------------------------------------------------------------------------- 2 VOGTLE 2 4542 100 -------------------------------------------------------------------------------- 2 WATTS BAR 1 4543 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 07/03/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 BIG ROCK POINT 1 4544 078 COASTDOWN TO DECOMMISSIONING - UNIT SCHEDULED TO SHUT DOWN ON 08/30/97 -------------------------------------------------------------------------------- 3 BRAIDWOOD 1 4545 100 -------------------------------------------------------------------------------- 3 BRAIDWOOD 2 4545 100 -------------------------------------------------------------------------------- 3 BYRON 1 4546 097 AT FULL POWER ADMINISTRATIVE LIMIT -------------------------------------------------------------------------------- 3 BYRON 2 4546 100 -------------------------------------------------------------------------------- 3 CLINTON 1 4548 000 09/96 07/15 COND 4 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 3 COOK 1 4549 100 -------------------------------------------------------------------------------- 3 COOK 2 4549 100 -------------------------------------------------------------------------------- 3 DAVIS BESSE 1 4550 100 -------------------------------------------------------------------------------- 3 DRESDEN 2 4551 099 * -------------------------------------------------------------------------------- 3 DRESDEN 3 4551 097 * -------------------------------------------------------------------------------- 3 DUANE ARNOLD 1 4552 100 -------------------------------------------------------------------------------- 3 FERMI 2 4553 096 -------------------------------------------------------------------------------- 3 KEWAUNEE 1 4554 094 TURBINE VALVES ARE FULL OPEN -------------------------------------------------------------------------------- 3 LASALLE 1 4555 000 09/96 12/15 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 LASALLE 2 4555 000 09/96 03/98 COND 5 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 3 MONTICELLO 1 4556 000 05/09 07/27 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 PALISADES 1 4557 100 -------------------------------------------------------------------------------- 3 PERRY 1 4558 100 -------------------------------------------------------------------------------- 3 POINT BEACH 1 4559 000 02/18 07/18 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 07/03/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 POINT BEACH 2 4559 000 10/96 07/08 MODE 6 - REFUELING REFUELING OUTAGE - FUEL RELOAD COMPLETE -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 1 4560 100 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 2 4560 100 -------------------------------------------------------------------------------- 3 QUAD CITIES 1 4561 100 * -------------------------------------------------------------------------------- 3 QUAD CITIES 2 4561 100 -------------------------------------------------------------------------------- 3 ZION 1 4562 000 02/21 UNK MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 3 ZION 2 4562 000 09/96 UNK MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 07/03/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 ARKANSAS NUCLEAR 1 4563 100 * -------------------------------------------------------------------------------- 4 ARKANSAS NUCLEAR 2 4563 100 -------------------------------------------------------------------------------- 4 CALLAWAY 1 4564 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 1 4565 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 2 4565 100 -------------------------------------------------------------------------------- 4 COOPER 1 4566 100 -------------------------------------------------------------------------------- 4 DIABLO CANYON 1 4567 100 -------------------------------------------------------------------------------- 4 DIABLO CANYON 2 4567 000 07/02 07/03 MODE 4 - HOT SHUTDOWN * # MANUAL REACTOR TRIP FROM 100% POWER DUE TO THE INABILITY TO MAINTAIN STEAM GENERATOR LEVELS BECAUSE OF THE LOSS OF FEEDWATER PUMP SUCTION (REFER TO EVENT #32572) - PLAN TO RESTART UNIT TODAY IF ROOT CAUSE CAN BE DETERMINED -------------------------------------------------------------------------------- 4 FT CALHOUN 1 4568 100 -------------------------------------------------------------------------------- 4 GRAND GULF 1 4569 100 -------------------------------------------------------------------------------- 4 PALO VERDE 1 4570 100 -------------------------------------------------------------------------------- 4 PALO VERDE 2 4570 100 -------------------------------------------------------------------------------- 4 PALO VERDE 3 4570 085 AT REDUCED LOAD DUE TO A * HEATER DRAIN PUMP DISCHARGE VALVE PACKING LEAK - REPAIR WORK COMPLETE -------------------------------------------------------------------------------- 4 RIVER BEND 1 4571 100 -------------------------------------------------------------------------------- 4 SAN ONOFRE 2 4572 000 06/29 07/15 MODE 5 - COLD SHUTDOWN * PLAN TO REPLACE CHARGING LINE CHECK VALVES - IN PROCESS OF DRAINING DOWN TO MID-LOOP -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 07/03/97 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 SAN ONOFRE 3 4572 000 04/11 07/12 MODE 5 - COLD SHUTDOWN * REFUELING OUTAGE - REPLACEMENT OF CHARGING LINE CHECK VALVES COMPLETE - PREPARING TO START REACTOR COOLANT PUMPS -------------------------------------------------------------------------------- 4 SOUTH TEXAS 1 4573 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 2 4573 100 -------------------------------------------------------------------------------- 4 WASHINGTON NUCLEAR 2 4574 000 03/27 07/04 COND 4 - COLD SHUTDOWN * EXITING REFUELING OUTAGE - WAITING ON NRC APPROVAL FOR UNIT RESTART -------------------------------------------------------------------------------- 4 WATERFORD 3 4575 000 04/11 UNK MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 4 WOLF CREEK 1 4576 100 -------------------------------------------------------------------------------- * - REASON OR COMMENT HAS BEEN CHANGED IN PAST 24 HOURS # - NUMBER OF REACTOR SCRAMS WITHIN PAST 24 HOURS NOTE - REACTOR STATUS DATA COLLECTED BETWEEN 4 A.M. AND 8 A.M. EACH DAY. ALL TIMES ARE BASED ON EASTERN TIMES (ET).