NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 01/31/96 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 BEAVER VALLEY 1 4501 100 -------------------------------------------------------------------------------- 1 BEAVER VALLEY 2 4501 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 1 4502 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 2 4502 100 -------------------------------------------------------------------------------- 1 FITZPATRICK 1 4503 100 -------------------------------------------------------------------------------- 1 GINNA 1 4504 097 -------------------------------------------------------------------------------- 1 HADDAM NECK 1 4505 100 -------------------------------------------------------------------------------- 1 HOPE CREEK 1 4506 000 11/95 02/25 COND 5 - REFUELING * REFUELING OUTAGE - FUEL LOAD AND SHUFFLE COMPLETE -------------------------------------------------------------------------------- 1 INDIAN POINT 2 4507 100 -------------------------------------------------------------------------------- 1 INDIAN POINT 3 4508 000 09/95 02/15 MODE 5 - COLD SHUTDOWN * MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 LIMERICK 1 4509 085 COASTDOWN TO REFUELING * OUTAGE. PLAN TO START REFUELING OUTAGE ON 02/02/96. -------------------------------------------------------------------------------- 1 LIMERICK 2 4509 100 -------------------------------------------------------------------------------- 1 MAINE YANKEE 1 4510 090 POWER LIMITED BY CORE COOLING AND CONTAINMENT PRESSURE ACCIDENT ANALYSIS -------------------------------------------------------------------------------- 1 MILLSTONE 1 4511 000 11/95 02/29 COND 5 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 MILLSTONE 2 4512 100 -------------------------------------------------------------------------------- 1 MILLSTONE 3 4513 100 -------------------------------------------------------------------------------- 1 NINE MILE POINT 1 4514 100 -------------------------------------------------------------------------------- 1 NINE MILE POINT 2 4514 100 -------------------------------------------------------------------------------- 1 OYSTER CREEK 1 4515 100 -------------------------------------------------------------------------------- 1 PEACH BOTTOM 2 4516 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 01/31/96 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 PEACH BOTTOM 3 4516 100 -------------------------------------------------------------------------------- 1 PILGRIM 1 4517 100 -------------------------------------------------------------------------------- 1 SALEM 1 4518 000 05/95 07/01 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 SALEM 2 4518 000 06/95 07/01 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 SEABROOK 1 4519 030 INCREASING POWER * -------------------------------------------------------------------------------- 1 SUSQUEHANNA 1 4520 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 2 4520 100 -------------------------------------------------------------------------------- 1 THREE MILE ISLAND 1 4521 100 -------------------------------------------------------------------------------- 1 VERMONT YANKEE 1 4522 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 01/31/96 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 BROWNS FERRY 1 4525 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BROWNS FERRY 2 4525 099 COASTDOWN TO REFUELING * OUTAGE. PLAN TO START REFUELING OUTAGE ON 03/22/96. -------------------------------------------------------------------------------- 2 BROWNS FERRY 3 4525 100 -------------------------------------------------------------------------------- 2 BRUNSWICK 1 4526 100 * -------------------------------------------------------------------------------- 2 BRUNSWICK 2 4526 057 COASTDOWN TO REFUELING * OUTAGE. PLAN TO START REFUELING OUTAGE ON 02/02/96. -------------------------------------------------------------------------------- 2 CATAWBA 1 4527 100 -------------------------------------------------------------------------------- 2 CATAWBA 2 4527 100 -------------------------------------------------------------------------------- 2 CRYSTAL RIVER 3 4528 100 -------------------------------------------------------------------------------- 2 FARLEY 1 4529 100 -------------------------------------------------------------------------------- 2 FARLEY 2 4529 016 PERFORMING STEAM * GENERATOR SODIUM FLUSH. SCHEDULED TO RETURN TO 100% POWER ON 02/01/96. -------------------------------------------------------------------------------- 2 HARRIS 1 4531 100 -------------------------------------------------------------------------------- 2 HATCH 1 4532 092 COASTDOWN TO REFUELING * OUTAGE -------------------------------------------------------------------------------- 2 HATCH 2 4532 100 -------------------------------------------------------------------------------- 2 MCGUIRE 1 4533 100 * -------------------------------------------------------------------------------- 2 MCGUIRE 2 4533 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 1 4534 072 COASTDOWN TO REFUELING * OUTAGE. PLAN TO START REFUELING OUTAGE ON 02/11/96. -------------------------------------------------------------------------------- 2 NORTH ANNA 2 4534 100 -------------------------------------------------------------------------------- 2 OCONEE 1 4535 100 -------------------------------------------------------------------------------- 2 OCONEE 2 4535 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 01/31/96 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 OCONEE 3 4535 100 -------------------------------------------------------------------------------- 2 ROBINSON 2 4536 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 1 4537 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 2 4537 100 -------------------------------------------------------------------------------- 2 ST LUCIE 1 4538 100 -------------------------------------------------------------------------------- 2 ST LUCIE 2 4538 100 -------------------------------------------------------------------------------- 2 SUMMER 1 4539 100 -------------------------------------------------------------------------------- 2 SURRY 1 4540 100 -------------------------------------------------------------------------------- 2 SURRY 2 4540 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 3 4541 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 4 4541 100 -------------------------------------------------------------------------------- 2 VOGTLE 1 4542 100 -------------------------------------------------------------------------------- 2 VOGTLE 2 4542 100 -------------------------------------------------------------------------------- 2 WATTS BAR 1 2249 002 MODE 2 - STARTUP COMPLETED LOW POWER TESTING. WAITING FOR PERMISSION TO INCREASE POWER. -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 01/31/96 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 BIG ROCK POINT 1 4544 000 01/05 03/06 COND 5 - REFUELING * REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 3 BRAIDWOOD 1 4545 100 -------------------------------------------------------------------------------- 3 BRAIDWOOD 2 4545 100 -------------------------------------------------------------------------------- 3 BYRON 1 4546 097 * -------------------------------------------------------------------------------- 3 BYRON 2 4546 100 -------------------------------------------------------------------------------- 3 CLINTON 1 4548 100 -------------------------------------------------------------------------------- 3 COOK 1 4549 100 -------------------------------------------------------------------------------- 3 COOK 2 4549 100 -------------------------------------------------------------------------------- 3 DAVIS BESSE 1 4550 100 -------------------------------------------------------------------------------- 3 DRESDEN 2 4551 000 06/95 02/22 COND 5 - REFUELING * REFUELING OUTAGE - FUEL LOAD COMPLETE -------------------------------------------------------------------------------- 3 DRESDEN 3 4551 100 -------------------------------------------------------------------------------- 3 DUANE ARNOLD 1 4552 100 -------------------------------------------------------------------------------- 3 FERMI 2 4553 096 -------------------------------------------------------------------------------- 3 KEWAUNEE 1 4554 098 -------------------------------------------------------------------------------- 3 LASALLE 1 4555 000 01/25 04/05 COND 5 - REFUELING * REFUELING OUTAGE - FUEL OFFLOAD HAS NOT COMMENCED -------------------------------------------------------------------------------- 3 LASALLE 2 4555 100 * -------------------------------------------------------------------------------- 3 MONTICELLO 1 4556 097 COASTDOWN TO REFUELING OUTAGE -------------------------------------------------------------------------------- 3 PALISADES 1 4557 030 INCREASING POWER * -------------------------------------------------------------------------------- 3 PERRY 1 4558 000 01/27 03/29 COND 5 - REFUELING * REFUELING OUTAGE -------------------------------------------------------------------------------- 3 POINT BEACH 1 4559 100 -------------------------------------------------------------------------------- 3 POINT BEACH 2 4559 090 FULL POWER LIMIT -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 01/31/96 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 PRAIRIE ISLAND 1 4560 000 01/05 02/14 MODE 6 - REFUELING * REFUELING OUTAGE - FUEL SHUFFLE IN PROGRESS -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 2 4560 100 -------------------------------------------------------------------------------- 3 QUAD CITIES 1 4561 093 COASTDOWN TO REFUELING OUTAGE. ENTER REFUELING OUTAGE 02/03/96. -------------------------------------------------------------------------------- 3 QUAD CITIES 2 4561 100 -------------------------------------------------------------------------------- 3 ZION 1 4562 100 -------------------------------------------------------------------------------- 3 ZION 2 4562 001 MODE 2 - STARTUP HOLDING REACTOR POWER AT 1%. TROUBLESHOOTING AUXILIARY FEEDWATER FLOW TO STEAM GENERATOR "2A" HEADER (NOT GETTING ENOUGH FLOW THROUGH VALVE INTO HEADER). FLOW IS WITHIN MIN TECH SPEC LIMITS. -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 01/31/96 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 ARKANSAS NUCLEAR 1 4563 080 PERFORMING WATERBOX * REPAIRS -------------------------------------------------------------------------------- 4 ARKANSAS NUCLEAR 2 4563 098 -------------------------------------------------------------------------------- 4 CALLAWAY 1 4564 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 1 4565 000 01/22 02/02 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 4 COMANCHE PEAK 2 4565 100 -------------------------------------------------------------------------------- 4 COOPER 1 4566 100 -------------------------------------------------------------------------------- 4 DIABLO CANYON 1 4567 100 -------------------------------------------------------------------------------- 4 DIABLO CANYON 2 4567 100 -------------------------------------------------------------------------------- 4 FT CALHOUN 1 4568 100 -------------------------------------------------------------------------------- 4 GRAND GULF 1 4569 100 -------------------------------------------------------------------------------- 4 PALO VERDE 1 4570 100 -------------------------------------------------------------------------------- 4 PALO VERDE 2 4570 100 -------------------------------------------------------------------------------- 4 PALO VERDE 3 4570 100 -------------------------------------------------------------------------------- 4 RIVER BEND 1 4571 000 01/04 02/11 COND 4 - COLD SHUTDOWN * # EXITING REFUELING OUTAGE. PREPARING FOR REACTOR VESSEL HYDRO. RECEIVED FULL SCRAM SIGNAL WHICH ACTUATED ALTERNATE ROD INSERTION. NO ROD MOTION BECAUSE RODS WERE ALREADY INSERTED. (REFER TO EVENT #29903.) -------------------------------------------------------------------------------- 4 SAN ONOFRE 2 4572 099 * -------------------------------------------------------------------------------- 4 SAN ONOFRE 3 4572 099 * -------------------------------------------------------------------------------- 4 SOUTH TEXAS 1 4573 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 2 4573 100 -------------------------------------------------------------------------------- 4 WASHINGTON NUCLEAR 2 4574 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 01/31/96 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 WATERFORD 3 4575 088 PERFORMING TURBINE VALVE * TESTING -------------------------------------------------------------------------------- 4 WOLF CREEK 1 4576 000 01/30 UNK MODE 4 - HOT SHUTDOWN * # MANUAL REACTOR TRIP DUE TO FREEZING OF THE CIRCULATION WATER SCREEN. TRAIN 'A' ESSENTIAL SERVICE WATER INOPERABLE. UNUSUAL EVENT DECLARED AND EXITED. (REFER TO EVENT #29904 AND EVENT # 29905.) -------------------------------------------------------------------------------- * - REASON OR COMMENT HAS BEEN CHANGED IN PAST 24 HOURS # - NUMBER OF REACTOR SCRAMS WITHIN PAST 24 HOURS NOTE - REACTOR STATUS DATA COLLECTED BETWEEN 4 A.M. AND 8 A.M. EACH DAY. ALL TIMES ARE BASED ON EASTERN TIMES (ET).