NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 09/11/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 BEAVER VALLEY 1 4501 100 -------------------------------------------------------------------------------- 1 BEAVER VALLEY 2 4501 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 1 4502 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 2 4502 100 -------------------------------------------------------------------------------- 1 FITZPATRICK 1 4503 001 COND 2 - STARTUP * IRMs ON RANGE 8 -------------------------------------------------------------------------------- 1 GINNA 1 4504 097 * -------------------------------------------------------------------------------- 1 HADDAM NECK 1 4505 100 -------------------------------------------------------------------------------- 1 HOPE CREEK 1 4506 100 -------------------------------------------------------------------------------- 1 INDIAN POINT 2 4507 100 -------------------------------------------------------------------------------- 1 INDIAN POINT 3 4508 100 -------------------------------------------------------------------------------- 1 LIMERICK 1 4509 100 -------------------------------------------------------------------------------- 1 LIMERICK 2 4509 100 -------------------------------------------------------------------------------- 1 MAINE YANKEE 1 4510 000 01/14 12/01 MODE 6 - REFUELING DEFUELED - SLEEVING STEAM GENERATOR TUBES -------------------------------------------------------------------------------- 1 MILLSTONE 1 4511 100 -------------------------------------------------------------------------------- 1 MILLSTONE 2 4512 100 -------------------------------------------------------------------------------- 1 MILLSTONE 3 4513 099 INCREASING REACTOR POWER * AFTER SHIFTING CONDENSATE PUMPS. -------------------------------------------------------------------------------- 1 NINE MILE POINT 1 4514 100 -------------------------------------------------------------------------------- 1 NINE MILE POINT 2 4514 000 09/06 09/11 COND 4 - COLD SHUTDOWN * LICENSEE WORKING ON "A" RESERVE TRANSFORMER. MIGHT START REACTOR UP TODAY OR TOMORROW. -------------------------------------------------------------------------------- 1 OYSTER CREEK 1 4515 100 -------------------------------------------------------------------------------- 1 PEACH BOTTOM 2 4516 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 09/11/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 PEACH BOTTOM 3 4516 060 END OF CYCLE COASTDOWN. REFUELING OUTAGE IS SCHEDULED TO COMMENCE 09/22/95. -------------------------------------------------------------------------------- 1 PILGRIM 1 4517 100 -------------------------------------------------------------------------------- 1 SALEM 1 4518 000 05/16 04/96 MODE 6 - REFUELING MAINTENANCE OUTAGE- DEFUELED -------------------------------------------------------------------------------- 1 SALEM 2 4518 000 06/07 07/96 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 SEABROOK 1 4519 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 1 4520 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 2 4520 100 -------------------------------------------------------------------------------- 1 THREE MILE ISLAND 1 4521 000 09/08 10/08 MODE 5 - COLD SHUTDOWN * ENTERING REFUELING OUTAGE. -------------------------------------------------------------------------------- 1 VERMONT YANKEE 1 4522 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 09/11/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 BROWNS FERRY 1 4525 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BROWNS FERRY 2 4525 100 -------------------------------------------------------------------------------- 2 BROWNS FERRY 3 4525 000 03/85 12/04 COND 5 - REFUELING DEFUELED - FUEL LOAD SCHEDULED FOR 10/95 -------------------------------------------------------------------------------- 2 BRUNSWICK 1 4526 100 -------------------------------------------------------------------------------- 2 BRUNSWICK 2 4526 095 COASTDOWN TO REFUELING * OUTAGE. -------------------------------------------------------------------------------- 2 CATAWBA 1 4527 100 -------------------------------------------------------------------------------- 2 CATAWBA 2 4527 100 -------------------------------------------------------------------------------- 2 CRYSTAL RIVER 3 4528 097 ONE REACTOR COOLANT PUMP * POWER MONITOR IS BYPASSED DUE TO IT HAVING A BAD POTENTIAL TRANSFORMER (PT). LICENSEE WILL HAVE TO TAKE THE ASSOCIATED REACTOR COOLANT PUMP OUT OF SERVICE IN ORDER TO REPLACE THE "PT". -------------------------------------------------------------------------------- 2 FARLEY 1 4529 081 COASTDOWN TO REFUELING * OUTAGE. OUTAGE IS SCHEDULED TO COMMENCE 09/15/95. -------------------------------------------------------------------------------- 2 FARLEY 2 4529 100 -------------------------------------------------------------------------------- 2 GRAND GULF 1 4530 100 -------------------------------------------------------------------------------- 2 HARRIS 1 4531 000 09/01 10/06 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 2 HATCH 1 4532 100 -------------------------------------------------------------------------------- 2 HATCH 2 4532 089 COASTDOWN TO REFUELING. OUTAGE IS SCHEDULED TO COMMENCE 09/23/95. -------------------------------------------------------------------------------- 2 MCGUIRE 1 4533 100 -------------------------------------------------------------------------------- 2 MCGUIRE 2 4533 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 09/11/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 NORTH ANNA 1 4534 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 2 4534 100 -------------------------------------------------------------------------------- 2 OCONEE 1 4535 100 -------------------------------------------------------------------------------- 2 OCONEE 2 4535 100 -------------------------------------------------------------------------------- 2 OCONEE 3 4535 100 -------------------------------------------------------------------------------- 2 ROBINSON 2 4536 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 1 4537 000 09/09 10/28 MODE 5 - COLD SHUTDOWN ENTERING REFUELING OUTAGE. -------------------------------------------------------------------------------- 2 SEQUOYAH 2 4537 100 -------------------------------------------------------------------------------- 2 ST LUCIE 1 4538 000 08/01 09/12 MODE 3 - HOT STANDBY INADVERTENT CONTAINMENT SPRAY ACTUATION WILL DELAY STARTUP. -------------------------------------------------------------------------------- 2 ST LUCIE 2 4538 100 -------------------------------------------------------------------------------- 2 SUMMER 1 4539 100 -------------------------------------------------------------------------------- 2 SURRY 1 4540 000 09/07 10/14 MODE 5 - COLD SHUTDOWN ENTERING REFUELING OUTAGE -------------------------------------------------------------------------------- 2 SURRY 2 4540 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 3 4541 000 09/03 10/08 MODE 6 - REFUELING REFUELING OUTAGE -------------------------------------------------------------------------------- 2 TURKEY POINT 4 4541 100 -------------------------------------------------------------------------------- 2 VOGTLE 1 4542 100 -------------------------------------------------------------------------------- 2 VOGTLE 2 4542 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 09/11/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 BIG ROCK POINT 1 4544 091 -------------------------------------------------------------------------------- 3 BRAIDWOOD 1 4545 097 STARTING COASTDOWN. * REFUELING OUTAGE SCHEDULED TO COMMENCE 09/30/95. -------------------------------------------------------------------------------- 3 BRAIDWOOD 2 4545 100 -------------------------------------------------------------------------------- 3 BYRON 1 4546 098 AT FULL POWER * -------------------------------------------------------------------------------- 3 BYRON 2 4546 060 LOAD FOLLOWING * -------------------------------------------------------------------------------- 3 CALLAWAY 1 4547 100 -------------------------------------------------------------------------------- 3 CLINTON 1 4548 001 COND 2 - STARTUP * IRMs ON RANGE 8. REACTOR VESSEL PRESSURE IS 326psig. -------------------------------------------------------------------------------- 3 COOK 1 4549 000 07/16 10/01 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 3 COOK 2 4549 000 09/08 09/11 MODE 3 - HOT STANDBY * MANUAL REACTOR TRIP DUE TO OPERATOR ERROR DURING SSPS TRAIN "A" TESTING. SEE EVENT # 29311. -------------------------------------------------------------------------------- 3 DAVIS BESSE 1 4550 100 -------------------------------------------------------------------------------- 3 DRESDEN 2 4551 000 06/05 09/30 COND 5 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 3 DRESDEN 3 4551 001 COND 2 - STARTUP * ADDING HEAT (IRMs ON RANGE 7). COMPLETING VALVE OPERATIONS. -------------------------------------------------------------------------------- 3 DUANE ARNOLD 1 4552 100 -------------------------------------------------------------------------------- 3 FERMI 2 4553 096 -------------------------------------------------------------------------------- 3 KEWAUNEE 1 4554 096 AT FULL POWER -------------------------------------------------------------------------------- 3 LASALLE 1 4555 082 PERFORMING CONTROL ROD * SET BEFORE INCREASING REACTOR POWER. -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 09/11/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 LASALLE 2 4555 083 WILL SHUTDOWN 09/15/95 TO TROUBLESHOOT SERVO OSCILLATION ON THEIR "2A" FCV WHEN IT IS UNLOCKED. -------------------------------------------------------------------------------- 3 MONTICELLO 1 4556 100 -------------------------------------------------------------------------------- 3 PALISADES 1 4557 100 -------------------------------------------------------------------------------- 3 PERRY 1 4558 100 * -------------------------------------------------------------------------------- 3 POINT BEACH 1 4559 100 -------------------------------------------------------------------------------- 3 POINT BEACH 2 4559 100 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 1 4560 100 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 2 4560 100 -------------------------------------------------------------------------------- 3 QUAD CITIES 1 4561 099 LOAD FOLLOWING * -------------------------------------------------------------------------------- 3 QUAD CITIES 2 4561 090 HOLDING POWER FOR * RECIRCULATION PUMP TESTING WHICH WILL BE PERFORMED LATER THIS WEEK. -------------------------------------------------------------------------------- 3 ZION 1 4562 000 09/09 11/12 MODE 4 - HOT SHUTDOWN ENTERING REFUELING OUTAGE. -------------------------------------------------------------------------------- 3 ZION 2 4562 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 09/11/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 ARKANSAS NUCLEAR 1 4563 100 -------------------------------------------------------------------------------- 4 ARKANSAS NUCLEAR 2 4563 098 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 1 4564 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 2 4564 100 -------------------------------------------------------------------------------- 4 COOPER 1 4565 095 COASTDOWN TO REFUELING * OUTAGE. OUTAGE IS SCHEDULED TO COMMENCE 10/12/95. -------------------------------------------------------------------------------- 4 DIABLO CANYON 1 4566 100 * -------------------------------------------------------------------------------- 4 DIABLO CANYON 2 4566 100 -------------------------------------------------------------------------------- 4 FT CALHOUN 1 4567 100 -------------------------------------------------------------------------------- 4 PALO VERDE 1 4568 099 -------------------------------------------------------------------------------- 4 PALO VERDE 2 4568 100 -------------------------------------------------------------------------------- 4 PALO VERDE 3 4568 100 -------------------------------------------------------------------------------- 4 RIVER BEND 1 4569 100 -------------------------------------------------------------------------------- 4 SAN ONOFRE 2 4571 100 * -------------------------------------------------------------------------------- 4 SAN ONOFRE 3 4571 000 07/22 10/09 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 4 SOUTH TEXAS 1 4572 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 2 4572 100 -------------------------------------------------------------------------------- 4 WASHINGTON NUCLEAR 2 4574 100 -------------------------------------------------------------------------------- 4 WATERFORD 3 4575 100 -------------------------------------------------------------------------------- 4 WOLF CREEK 1 4576 100 -------------------------------------------------------------------------------- * - REASON OR COMMENT HAS BEEN CHANGED IN PAST 24 HOURS # - NUMBER OF REACTOR SCRAMS WITHIN PAST 24 HOURS NOTE - REACTOR STATUS DATA COLLECTED BETWEEN 4 A.M. AND 8 A.M. EACH DAY. ALL TIMES ARE BASED ON EASTERN TIMES (ET).