NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 12/08/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 BEAVER VALLEY 1 4501 100 -------------------------------------------------------------------------------- 1 BEAVER VALLEY 2 4501 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 1 4502 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 2 4502 100 -------------------------------------------------------------------------------- 1 FITZPATRICK 1 4503 100 -------------------------------------------------------------------------------- 1 GINNA 1 4504 097 -------------------------------------------------------------------------------- 1 HADDAM NECK 1 4505 100 -------------------------------------------------------------------------------- 1 HOPE CREEK 1 4506 000 11/10 UNK COND 5 - REFUELING REFUELING OUTAGE. LESS THAN 10% OF FUEL OFFLOADED. CORE ALTERATIONS ARE NOT IN PROGRESS AT THIS TIME. -------------------------------------------------------------------------------- 1 INDIAN POINT 2 4507 100 -------------------------------------------------------------------------------- 1 INDIAN POINT 3 4508 000 09/14 12/10 MODE 4 - HOT SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 LIMERICK 1 4509 100 -------------------------------------------------------------------------------- 1 LIMERICK 2 4509 100 -------------------------------------------------------------------------------- 1 MAINE YANKEE 1 4510 000 01/14 12/24 MODE 6 - REFUELING REFUELING OUTAGE - FUEL RELOADED. SLEEVING STEAM GENERATOR TUBES. -------------------------------------------------------------------------------- 1 MILLSTONE 1 4511 000 11/04 01/96 COND 5 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 MILLSTONE 2 4512 100 * -------------------------------------------------------------------------------- 1 MILLSTONE 3 4513 000 11/30 12/14 MODE 5 - COLD SHUTDOWN * REPAIRING RSC PRESSURE BOUNDARY LEAKS (SEE EVENT NUMBER 29660) -------------------------------------------------------------------------------- 1 NINE MILE POINT 1 4514 100 -------------------------------------------------------------------------------- 1 NINE MILE POINT 2 4514 100 -------------------------------------------------------------------------------- 1 OYSTER CREEK 1 4515 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 12/08/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 PEACH BOTTOM 2 4516 000 12/01 12/08 COND 2 - STARTUP * STARTUP IN PROGRESS FOLLOWING PLANNED FEEDWATER PUMP MAINTENANCE OUTAGE (REACTOR CRITICAL) - PLAN TO PLACE UNIT ON LINE TODAY -------------------------------------------------------------------------------- 1 PEACH BOTTOM 3 4516 098 INCREASING POWER * -------------------------------------------------------------------------------- 1 PILGRIM 1 4517 100 -------------------------------------------------------------------------------- 1 SALEM 1 4518 000 05/16 04/96 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 SALEM 2 4518 000 06/07 07/96 MODE 6 - REFUELING * MAINTENANCE OUTAGE - MAKING PREPARATIONS TO REMOVE THE HEAD -------------------------------------------------------------------------------- 1 SEABROOK 1 4519 000 11/03 12/09 MODE 3 - HOT STANDBY EXITING REFUELING OUTAGE -------------------------------------------------------------------------------- 1 SUSQUEHANNA 1 4520 098 INCREASING POWER * -------------------------------------------------------------------------------- 1 SUSQUEHANNA 2 4520 100 -------------------------------------------------------------------------------- 1 THREE MILE ISLAND 1 4521 100 -------------------------------------------------------------------------------- 1 VERMONT YANKEE 1 4522 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 12/08/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 BROWNS FERRY 1 4525 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BROWNS FERRY 2 4525 100 -------------------------------------------------------------------------------- 2 BROWNS FERRY 3 4525 080 ESTABLISHING A ROD * PATTERN AND EXPECT TO INCREASE POWER TODAY -------------------------------------------------------------------------------- 2 BRUNSWICK 1 4526 100 -------------------------------------------------------------------------------- 2 BRUNSWICK 2 4526 080 COASTDOWN TO REFUELING OUTAGE -------------------------------------------------------------------------------- 2 CATAWBA 1 4527 100 -------------------------------------------------------------------------------- 2 CATAWBA 2 4527 100 -------------------------------------------------------------------------------- 2 CRYSTAL RIVER 3 4528 100 -------------------------------------------------------------------------------- 2 FARLEY 1 4529 100 -------------------------------------------------------------------------------- 2 FARLEY 2 4529 100 -------------------------------------------------------------------------------- 2 HARRIS 1 4531 100 -------------------------------------------------------------------------------- 2 HATCH 1 4532 100 -------------------------------------------------------------------------------- 2 HATCH 2 4532 100 -------------------------------------------------------------------------------- 2 MCGUIRE 1 4533 093 COASTDOWN TO REFUELING * OUTAGE -------------------------------------------------------------------------------- 2 MCGUIRE 2 4533 100 * -------------------------------------------------------------------------------- 2 NORTH ANNA 1 4534 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 2 4534 100 -------------------------------------------------------------------------------- 2 OCONEE 1 4535 000 11/02 12/09 MODE 4 - HOT SHUTDOWN EXITING REFUELING OUTAGE -------------------------------------------------------------------------------- 2 OCONEE 2 4535 100 -------------------------------------------------------------------------------- 2 OCONEE 3 4535 100 -------------------------------------------------------------------------------- 2 ROBINSON 2 4536 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 1 4537 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 2 4537 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 12/08/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 ST LUCIE 1 4538 100 -------------------------------------------------------------------------------- 2 ST LUCIE 2 4538 000 10/09 12/10 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 2 SUMMER 1 4539 100 -------------------------------------------------------------------------------- 2 SURRY 1 4540 078 INCREASING POWER * -------------------------------------------------------------------------------- 2 SURRY 2 4540 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 3 4541 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 4 4541 100 -------------------------------------------------------------------------------- 2 VOGTLE 1 4542 100 -------------------------------------------------------------------------------- 2 VOGTLE 2 4542 100 -------------------------------------------------------------------------------- 2 WATTS BAR 1 2249 000 11/09 UNK MODE 5 - COLD SHUTDOWN * REACTOR TRIP SIGNAL GENERATED WHILE IN MODE 5 (SEE EVENT NUMBER 29679) -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 12/08/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 BIG ROCK POINT 1 4544 066 COASTDOWN TO REFUELING OUTAGE -------------------------------------------------------------------------------- 3 BRAIDWOOD 1 4545 000 09/29 12/09 MODE 3 - HOT STANDBY * # EXITING REFUELING OUTAGE - MANUAL REACTOR TRIPS WHILE IN MODE 3 (SEE EVENT NUMBERS 29682, 29683, AND 29684) -------------------------------------------------------------------------------- 3 BRAIDWOOD 2 4545 100 -------------------------------------------------------------------------------- 3 BYRON 1 4546 000 10/22 12/25 MODE 5 - COLD SHUTDOWN STEAM GENERATOR TUBE INSPECTION OUTAGE -------------------------------------------------------------------------------- 3 BYRON 2 4546 099 -------------------------------------------------------------------------------- 3 CLINTON 1 4548 100 -------------------------------------------------------------------------------- 3 COOK 1 4549 000 12/07 12/10 MODE 3 - HOT STANDBY * # MANUAL REACTOR TRIP FROM 32% DUE TO TURBINE BEARING VIBRATIONS DURING POWER REDUCTION FOR PLANNED MAINTENANCE (SEE EVENT NUMBER 29685) -------------------------------------------------------------------------------- 3 COOK 2 4549 093 RECALIBRATING REHEATER * DRAIN LEVEL SWITCH - MOISTURE SEPARATER REHEATOR REHEATER BUNBLES OUT OF SERVICE -------------------------------------------------------------------------------- 3 DAVIS BESSE 1 4550 100 -------------------------------------------------------------------------------- 3 DRESDEN 2 4551 000 06/05 01/96 COND 5 - REFUELING REFUELING OUTAGE - DEFUELED OUTAGE DELAYED UNTIL 1/96 -------------------------------------------------------------------------------- 3 DRESDEN 3 4551 100 -------------------------------------------------------------------------------- 3 DUANE ARNOLD 1 4552 100 -------------------------------------------------------------------------------- 3 FERMI 2 4553 096 -------------------------------------------------------------------------------- 3 KEWAUNEE 1 4554 098 -------------------------------------------------------------------------------- 3 LASALLE 1 4555 081 COASTDOWN TO REFUELING * OUTAGE -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 12/08/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 LASALLE 2 4555 099 INCREASING POWER * -------------------------------------------------------------------------------- 3 MONTICELLO 1 4556 100 -------------------------------------------------------------------------------- 3 PALISADES 1 4557 100 * -------------------------------------------------------------------------------- 3 PERRY 1 4558 095 COASTDOWN TO REFUELING OUTAGE -------------------------------------------------------------------------------- 3 POINT BEACH 1 4559 100 -------------------------------------------------------------------------------- 3 POINT BEACH 2 4559 088 HOLDING AT THIS POWER LEVEL TO PERFORM AXIAL OFFSET TESTING -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 1 4560 100 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 2 4560 100 -------------------------------------------------------------------------------- 3 QUAD CITIES 1 4561 100 -------------------------------------------------------------------------------- 3 QUAD CITIES 2 4561 100 -------------------------------------------------------------------------------- 3 ZION 1 4562 000 09/09 12/13 MODE 3 - HOT STANDBY * EXITING REFUELING OUTAGE -------------------------------------------------------------------------------- 3 ZION 2 4562 000 12/07 12/09 MODE 3 - HOT STANDBY * REPAIRING UNISOLABLE TURBINE EHC LEAK AND LEAK ON LETDOWN ISOLATION VALVE -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 12/08/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 ARKANSAS NUCLEAR 1 4563 100 -------------------------------------------------------------------------------- 4 ARKANSAS NUCLEAR 2 4563 097 * -------------------------------------------------------------------------------- 4 CALLAWAY 1 4564 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 1 4565 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 2 4565 000 12/05 12/08 MODE 3 - HOT STANDBY * AUTOMATIC REACTOR TRIP ON LOW STEAM GENERATOR LEVEL (SEE EVENT #29670) - PREPARING TO ENTER MODE 2 -------------------------------------------------------------------------------- 4 COOPER 1 4566 000 10/14 12/19 COND 4 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 4 DIABLO CANYON 1 4567 100 * -------------------------------------------------------------------------------- 4 DIABLO CANYON 2 4567 100 -------------------------------------------------------------------------------- 4 FT CALHOUN 1 4568 100 -------------------------------------------------------------------------------- 4 GRAND GULF 1 4569 100 -------------------------------------------------------------------------------- 4 PALO VERDE 1 4570 040 TRYING TO FIND CONDENSER * TUBE LEAK -------------------------------------------------------------------------------- 4 PALO VERDE 2 4570 100 -------------------------------------------------------------------------------- 4 PALO VERDE 3 4570 100 -------------------------------------------------------------------------------- 4 RIVER BEND 1 4571 089 COASTDOWN TO REFUELING OUTAGE -------------------------------------------------------------------------------- 4 SAN ONOFRE 2 4572 100 -------------------------------------------------------------------------------- 4 SAN ONOFRE 3 4572 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 1 4573 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 2 4573 100 -------------------------------------------------------------------------------- 4 WASHINGTON NUCLEAR 2 4574 060 POWER NOT NEEDED - * ECONOMIC DISPATCH UNTIL 12/11/95 -------------------------------------------------------------------------------- 4 WATERFORD 3 4575 100 -------------------------------------------------------------------------------- 4 WOLF CREEK 1 4576 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 12/08/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - * - REASON OR COMMENT HAS BEEN CHANGED IN PAST 24 HOURS # - NUMBER OF REACTOR SCRAMS WITHIN PAST 24 HOURS NOTE - REACTOR STATUS DATA COLLECTED BETWEEN 4 A.M. AND 8 A.M. EACH DAY. ALL TIMES ARE BASED ON EASTERN TIMES (ET).