NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 11/06/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 BEAVER VALLEY 1 4501 100 * -------------------------------------------------------------------------------- 1 BEAVER VALLEY 2 4501 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 1 4502 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 2 4502 100 -------------------------------------------------------------------------------- 1 FITZPATRICK 1 4503 100 -------------------------------------------------------------------------------- 1 GINNA 1 4504 096 * -------------------------------------------------------------------------------- 1 HADDAM NECK 1 4505 100 -------------------------------------------------------------------------------- 1 HOPE CREEK 1 4506 087 COASTDOWN TO REFUELING * OUTAGE -------------------------------------------------------------------------------- 1 INDIAN POINT 2 4507 100 -------------------------------------------------------------------------------- 1 INDIAN POINT 3 4508 000 09/14 11/20 MODE 5 - COLD SHUTDOWN * MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 LIMERICK 1 4509 100 -------------------------------------------------------------------------------- 1 LIMERICK 2 4509 100 -------------------------------------------------------------------------------- 1 MAINE YANKEE 1 4510 000 01/14 12/20 MODE 6 - REFUELING REFUELING OUTAGE - SLEEVING STEAM GENERATOR TUBES/FUEL IS APPROXIMATELY 50% RELOADED. FUEL RELOAD IS NOT IN PROGRESS BUT WILL RECOMMENCE MID- WEEK. -------------------------------------------------------------------------------- 1 MILLSTONE 1 4511 000 11/04 12/24 COND 4 - COLD SHUTDOWN * REFUELING OUTAGE -------------------------------------------------------------------------------- 1 MILLSTONE 2 4512 100 -------------------------------------------------------------------------------- 1 MILLSTONE 3 4513 100 -------------------------------------------------------------------------------- 1 NINE MILE POINT 1 4514 100 -------------------------------------------------------------------------------- 1 NINE MILE POINT 2 4514 100 -------------------------------------------------------------------------------- 1 OYSTER CREEK 1 4515 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 11/06/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 PEACH BOTTOM 2 4516 095 FEEDWATER HEATER STRING OUT OF SERVICE DUE TO A FEEDWATER HEATER TUBE LEAK -------------------------------------------------------------------------------- 1 PEACH BOTTOM 3 4516 100 -------------------------------------------------------------------------------- 1 PILGRIM 1 4517 100 -------------------------------------------------------------------------------- 1 SALEM 1 4518 000 05/16 04/96 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 1 SALEM 2 4518 000 06/07 07/96 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 SEABROOK 1 4519 000 11/03 12/09 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 1 SUSQUEHANNA 1 4520 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 2 4520 100 -------------------------------------------------------------------------------- 1 THREE MILE ISLAND 1 4521 100 -------------------------------------------------------------------------------- 1 VERMONT YANKEE 1 4522 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 11/06/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 BROWNS FERRY 1 4525 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BROWNS FERRY 2 4525 100 -------------------------------------------------------------------------------- 2 BROWNS FERRY 3 4525 000 03/85 12/08 COND 4 - COLD SHUTDOWN REFUELED - PLAN TO PERFORM ILLRT ON 11/06 FOLLOWED BY VESSEL HYDO - PLAN TO PLACE MODE SWITCH IN STARTUP ON 11/17 -------------------------------------------------------------------------------- 2 BRUNSWICK 1 4526 100 -------------------------------------------------------------------------------- 2 BRUNSWICK 2 4526 090 COASTDOWN TO REFUELING * OUTAGE -------------------------------------------------------------------------------- 2 CATAWBA 1 4527 100 -------------------------------------------------------------------------------- 2 CATAWBA 2 4527 000 10/06 11/16 MODE 6 - REFUELING * REFUELING OUTAGE - REFUELED -------------------------------------------------------------------------------- 2 CRYSTAL RIVER 3 4528 100 -------------------------------------------------------------------------------- 2 FARLEY 1 4529 001 MODE 2 - STARTUP * LOAD REDUCTION FROM 27% POWER AND ESF ACTUATION BECAUSE MAIN FEEDWATER PUMP 'B' TRIPPED ON LOW LUBE OIL PRESSURE. THIS CAUSED MAIN FEEDWATER ISOLATION AND AUTOMATIC START OF MOTOR-DRIVEN AFW PUMPS. (REFER TO EVENT #29562.) -------------------------------------------------------------------------------- 2 FARLEY 2 4529 100 -------------------------------------------------------------------------------- 2 HARRIS 1 4531 000 11/05 11/07 MODE 4 - HOT SHUTDOWN * # CONTACT ON A BLOCKING RELAY FAILED TO MAKE UP DURING ESF SYSTEM TESTING AND CAUSED CLOSURE OF AN MSIV. SUBSEQUENT PRESSURE TRANSIENT INITIATED SI AND REACTOR TRIP. UNUSUAL EVENT DECLARED. (REFER TO EVENT #29561.) -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 11/06/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 HATCH 1 4532 100 -------------------------------------------------------------------------------- 2 HATCH 2 4532 000 09/22 11/10 COND 4 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 2 MCGUIRE 1 4533 100 -------------------------------------------------------------------------------- 2 MCGUIRE 2 4533 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 1 4534 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 2 4534 100 -------------------------------------------------------------------------------- 2 OCONEE 1 4535 000 11/02 12/04 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 2 OCONEE 2 4535 100 -------------------------------------------------------------------------------- 2 OCONEE 3 4535 100 -------------------------------------------------------------------------------- 2 ROBINSON 2 4536 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 1 4537 000 09/09 11/08 MODE 5 - COLD SHUTDOWN * REFUELING OUTAGE - REPLACED RCP MOTOR. CORRECTING ERCW HANGER DEFICIENCY. PLAN TO ENTER MODE 4 TODAY. -------------------------------------------------------------------------------- 2 SEQUOYAH 2 4537 100 -------------------------------------------------------------------------------- 2 ST LUCIE 1 4538 100 -------------------------------------------------------------------------------- 2 ST LUCIE 2 4538 000 10/09 11/19 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 2 SUMMER 1 4539 100 -------------------------------------------------------------------------------- 2 SURRY 1 4540 100 -------------------------------------------------------------------------------- 2 SURRY 2 4540 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 3 4541 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 4 4541 100 -------------------------------------------------------------------------------- 2 VOGTLE 1 4542 100 -------------------------------------------------------------------------------- 2 VOGTLE 2 4542 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 11/06/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 BIG ROCK POINT 1 4544 072 COASTDOWN TO REFUELING OUTAGE -------------------------------------------------------------------------------- 3 BRAIDWOOD 1 4545 000 09/29 11/20 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 3 BRAIDWOOD 2 4545 100 -------------------------------------------------------------------------------- 3 BYRON 1 4546 000 10/22 11/30 MODE 5 - COLD SHUTDOWN STEAM GENERATOR TUBE INSPECTION OUTAGE -------------------------------------------------------------------------------- 3 BYRON 2 4546 100 -------------------------------------------------------------------------------- 3 CLINTON 1 4548 100 * -------------------------------------------------------------------------------- 3 COOK 1 4549 000 10/29 11/06 MODE 3 - HOT STANDBY * REDUCED HIGH SODIUM CONCENTRATION IN STEAM GENERATORS. PLAN TO GO CRITICAL AND PLACE TURBINE ON LINE LATER TODAY. -------------------------------------------------------------------------------- 3 COOK 2 4549 100 -------------------------------------------------------------------------------- 3 DAVIS BESSE 1 4550 100 -------------------------------------------------------------------------------- 3 DRESDEN 2 4551 000 06/05 12/12 COND 5 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 3 DRESDEN 3 4551 000 10/29 11/06 COND 5 - REFUELING * MANUAL SCRAM DUE TO DEBRIS IN PLANT INTAKE TRAVELING SCREENS. PREPARING FOR STARTUP. PLAN TO PLACE TURBINE ON LINE LATER TODAY OR EARLY TOMORROW. -------------------------------------------------------------------------------- 3 DUANE ARNOLD 1 4552 100 * -------------------------------------------------------------------------------- 3 FERMI 2 4553 096 FUEL LEAKER IN CONTROL * CELL 10-47 (SUPPRESSED) -------------------------------------------------------------------------------- 3 KEWAUNEE 1 4554 098 -------------------------------------------------------------------------------- 3 LASALLE 1 4555 090 REPLACING SCRAM SOLENOID * PILOT VALVES -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 11/06/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 LASALLE 2 4555 100 -------------------------------------------------------------------------------- 3 MONTICELLO 1 4556 100 -------------------------------------------------------------------------------- 3 PALISADES 1 4557 100 -------------------------------------------------------------------------------- 3 PERRY 1 4558 070 MOVING RODS TO LOCATE A * VERY SMALL CLAD PERFORATION. MAY HAVE LOCATED ONE FUEL LEAK. CONTINUING TO LOOK. -------------------------------------------------------------------------------- 3 POINT BEACH 1 4559 100 -------------------------------------------------------------------------------- 3 POINT BEACH 2 4559 000 10/07 12/01 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 1 4560 100 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 2 4560 100 -------------------------------------------------------------------------------- 3 QUAD CITIES 1 4561 000 10/22 11/06 COND 4 - COLD SHUTDOWN DESIGN PROBLEM IN SCRAM DISCHARGE VOLUME HIGH LEVEL REACTOR SCRAM LOGIC -------------------------------------------------------------------------------- 3 QUAD CITIES 2 4561 000 10/21 11/20 COND 4 - COLD SHUTDOWN DESIGN PROBLEM IN SCRAM DISCHARGE VOLUME HIGH LEVEL REACTOR SCRAM LOGIC -------------------------------------------------------------------------------- 3 ZION 1 4562 000 09/09 12/01 MODE 6 - REFUELING * REFUELING OUTAGE - RELOADING FUEL (APPROXIMATELY 96% COMPLETE) -------------------------------------------------------------------------------- 3 ZION 2 4562 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 11/06/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 ARKANSAS NUCLEAR 1 4563 100 -------------------------------------------------------------------------------- 4 ARKANSAS NUCLEAR 2 4563 000 09/22 11/18 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 4 CALLAWAY 1 4564 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 1 4565 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 2 4565 100 -------------------------------------------------------------------------------- 4 COOPER 1 4566 000 10/14 12/08 COND 5 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 4 DIABLO CANYON 1 4567 000 09/30 11/22 MODE 6 - REFUELING REFUELING OUTAGE - REFUELED. AUXILIARY TRANSFORMER REPLACEMENT WILL DELAY STARTUP. PERFORMING STEAM GENERATOR EDDY CURRENT TESTING. -------------------------------------------------------------------------------- 4 DIABLO CANYON 2 4567 100 -------------------------------------------------------------------------------- 4 FT CALHOUN 1 4568 100 -------------------------------------------------------------------------------- 4 GRAND GULF 1 4569 100 -------------------------------------------------------------------------------- 4 PALO VERDE 1 4570 100 -------------------------------------------------------------------------------- 4 PALO VERDE 2 4570 100 -------------------------------------------------------------------------------- 4 PALO VERDE 3 4570 000 10/14 12/05 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 4 RIVER BEND 1 4571 096 COASTDOWN TO REFUELING * OUTAGE -------------------------------------------------------------------------------- 4 SAN ONOFRE 2 4572 100 -------------------------------------------------------------------------------- 4 SAN ONOFRE 3 4572 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 1 4573 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 2 4573 090 HOLDING POWER TO PERFORM * DELTA-T CALIBRATIONS -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 11/06/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 WASHINGTON NUCLEAR 2 4574 080 SLOWLY INCREASING POWER * FOLLOWING PERFORMANCE OF ROD SCRAM TIME TESTING AND CRD HCU SOLENOID PILOT VALVE WORK -------------------------------------------------------------------------------- 4 WATERFORD 3 4575 018 PERFORMING TURBINE * OVERSPEED TESTING -------------------------------------------------------------------------------- 4 WOLF CREEK 1 4576 100 -------------------------------------------------------------------------------- * - REASON OR COMMENT HAS BEEN CHANGED IN PAST 24 HOURS # - NUMBER OF REACTOR SCRAMS WITHIN PAST 24 HOURS NOTE - REACTOR STATUS DATA COLLECTED BETWEEN 4 A.M. AND 8 A.M. EACH DAY. ALL TIMES ARE BASED ON EASTERN TIMES (ET).