NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 06/12/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 BEAVER VALLEY 1 4501 100 -------------------------------------------------------------------------------- 1 BEAVER VALLEY 2 4501 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 1 4502 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 2 4502 095 PERFORMING MAINTENANCE ON A HEATER DRAIN PUMP -------------------------------------------------------------------------------- 1 FITZPATRICK 1 4503 083 INCREASING POWER * -------------------------------------------------------------------------------- 1 GINNA 1 4504 097 -------------------------------------------------------------------------------- 1 HADDAM NECK 1 4505 065 CLEANING MAIN CONDENSER TUBES -------------------------------------------------------------------------------- 1 HOPE CREEK 1 4506 100 -------------------------------------------------------------------------------- 1 INDIAN POINT 2 4507 090 HOLDING FOR TESTING * -------------------------------------------------------------------------------- 1 INDIAN POINT 3 4508 000 02/93 06/30 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE - - - REPAIRING REACTOR VESSEL HEAD SEAL LEAKS -------------------------------------------------------------------------------- 1 LIMERICK 1 4509 100 -------------------------------------------------------------------------------- 1 LIMERICK 2 4509 100 -------------------------------------------------------------------------------- 1 MAINE YANKEE 1 4510 000 01/14 12/01 MODE 6 - REFUELING REFUELING OUTAGE - - - - DEFUELED - SLEEVING STEAM GENERATOR TUBES -------------------------------------------------------------------------------- 1 MILLSTONE 1 4511 100 -------------------------------------------------------------------------------- 1 MILLSTONE 2 4512 000 09/94 06/26 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 1 MILLSTONE 3 4513 100 * -------------------------------------------------------------------------------- 1 NINE MILE POINT 1 4514 100 -------------------------------------------------------------------------------- 1 NINE MILE POINT 2 4514 090 HOLDING FOR POWER UP- * RATE TESTING -------------------------------------------------------------------------------- 1 OYSTER CREEK 1 4515 100 -------------------------------------------------------------------------------- 1 PEACH BOTTOM 2 4516 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 06/12/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 PEACH BOTTOM 3 4516 084 COASTDOWN TO REFUELING OUTAGE -------------------------------------------------------------------------------- 1 PILGRIM 1 4517 088 INCREASING POWER * -------------------------------------------------------------------------------- 1 SALEM 1 4518 000 05/16 07/05 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 SALEM 2 4518 000 06/07 UNK MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 SEABROOK 1 4519 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 1 4520 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 2 4520 100 -------------------------------------------------------------------------------- 1 THREE MILE ISLAND 1 4521 100 -------------------------------------------------------------------------------- 1 VERMONT YANKEE 1 4522 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 06/12/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 BROWNS FERRY 1 4525 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BROWNS FERRY 2 4525 100 -------------------------------------------------------------------------------- 2 BROWNS FERRY 3 4525 000 03/85 02/96 COND 5 - REFUELING DEFUELED - FUEL LOAD SCHEDULED FOR 10/95 -------------------------------------------------------------------------------- 2 BRUNSWICK 1 4526 100 -------------------------------------------------------------------------------- 2 BRUNSWICK 2 4526 100 -------------------------------------------------------------------------------- 2 CATAWBA 1 4527 100 -------------------------------------------------------------------------------- 2 CATAWBA 2 4527 100 -------------------------------------------------------------------------------- 2 CRYSTAL RIVER 3 4528 100 -------------------------------------------------------------------------------- 2 FARLEY 1 4529 000 06/11 06/16 MODE 3 - HOT STANDBY * # RX TRIP WHEN THE 'C' MSIV CLOSED. GOING TO MODE 5 TO INSPECT THE MSIV. SEE #28930. -------------------------------------------------------------------------------- 2 FARLEY 2 4529 014 CONTINUING TO * INVESTIGATE MAIN FEED PUMP PROBLEMS. MAY GO ON-LINE TODAY. -------------------------------------------------------------------------------- 2 GRAND GULF 1 4530 000 06/11 06/13 COND 3 - HOT SHUTDOWN * COOLING DOWN TO MODE 5 TO WORK ON A FAILED SEAL ON THE 'A' RECIRC PUMP. -------------------------------------------------------------------------------- 2 HARRIS 1 4531 100 -------------------------------------------------------------------------------- 2 HATCH 1 4532 100 -------------------------------------------------------------------------------- 2 HATCH 2 4532 100 * -------------------------------------------------------------------------------- 2 MCGUIRE 1 4533 100 -------------------------------------------------------------------------------- 2 MCGUIRE 2 4533 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 1 4534 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 2 4534 100 -------------------------------------------------------------------------------- 2 OCONEE 1 4535 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 06/12/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 OCONEE 2 4535 100 -------------------------------------------------------------------------------- 2 OCONEE 3 4535 000 06/06 07/20 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 2 ROBINSON 2 4536 000 04/28 06/23 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE - - - REPAIRING 'C' RCP FLANGE -------------------------------------------------------------------------------- 2 SEQUOYAH 1 4537 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 2 4537 099 -------------------------------------------------------------------------------- 2 ST LUCIE 1 4538 080 INCREASING POWER * -------------------------------------------------------------------------------- 2 ST LUCIE 2 4538 100 * -------------------------------------------------------------------------------- 2 SUMMER 1 4539 100 -------------------------------------------------------------------------------- 2 SURRY 1 4540 100 -------------------------------------------------------------------------------- 2 SURRY 2 4540 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 3 4541 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 4 4541 100 * -------------------------------------------------------------------------------- 2 VOGTLE 1 4542 100 -------------------------------------------------------------------------------- 2 VOGTLE 2 4542 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 06/12/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 BIG ROCK POINT 1 4544 095 -------------------------------------------------------------------------------- 3 BRAIDWOOD 1 4545 090 LOAD FOLLOWING * -------------------------------------------------------------------------------- 3 BRAIDWOOD 2 4545 100 -------------------------------------------------------------------------------- 3 BYRON 1 4546 098 -------------------------------------------------------------------------------- 3 BYRON 2 4546 100 -------------------------------------------------------------------------------- 3 CALLAWAY 1 4547 100 -------------------------------------------------------------------------------- 3 CLINTON 1 4548 100 -------------------------------------------------------------------------------- 3 COOK 1 4549 100 -------------------------------------------------------------------------------- 3 COOK 2 4549 100 -------------------------------------------------------------------------------- 3 DAVIS BESSE 1 4550 100 * -------------------------------------------------------------------------------- 3 DRESDEN 2 4551 000 06/05 09/05 COND 4 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 3 DRESDEN 3 4551 000 05/28 06/27 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 DUANE ARNOLD 1 4552 100 -------------------------------------------------------------------------------- 3 FERMI 2 4553 000 06/02 06/23 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 KEWAUNEE 1 4554 096 -------------------------------------------------------------------------------- 3 LASALLE 1 4555 000 06/11 06/18 COND 3 - HOT SHUTDOWN * COOLING DOWN FOR AN MSIV PROBLEM. SEE #28926. -------------------------------------------------------------------------------- 3 LASALLE 2 4555 015 PREPARING FOR TURBINE * OVER-SPEED TEST. -------------------------------------------------------------------------------- 3 MONTICELLO 1 4556 100 -------------------------------------------------------------------------------- 3 PALISADES 1 4557 000 05/22 08/22 MODE 6 - REFUELING REFUELING OUTAGE -------------------------------------------------------------------------------- 3 PERRY 1 4558 100 -------------------------------------------------------------------------------- 3 POINT BEACH 1 4559 100 -------------------------------------------------------------------------------- 3 POINT BEACH 2 4559 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 06/12/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 PRAIRIE ISLAND 1 4560 100 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 2 4560 000 05/12 06/19 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 3 QUAD CITIES 1 4561 070 LOAD FOLLOWING * -------------------------------------------------------------------------------- 3 QUAD CITIES 2 4561 000 03/05 06/23 COND 5 - REFUELING REFUELING OUTAGE -------------------------------------------------------------------------------- 3 ZION 1 4562 100 -------------------------------------------------------------------------------- 3 ZION 2 4562 091 LOAD FOLLOWING * -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 06/12/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 ARKANSAS NUCLEAR 1 4563 100 -------------------------------------------------------------------------------- 4 ARKANSAS NUCLEAR 2 4563 098 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 1 4564 000 06/11 UNK MODE 3 - HOT STANDBY * # MANUAL TRIP ON LOSS OF FEEDWATER. STILL INVESTIGATING TDAFP PROBLEM. SEE #28927. -------------------------------------------------------------------------------- 4 COMANCHE PEAK 2 4564 100 -------------------------------------------------------------------------------- 4 COOPER 1 4565 100 -------------------------------------------------------------------------------- 4 DIABLO CANYON 1 4566 081 LOAD FOLLOWING * -------------------------------------------------------------------------------- 4 DIABLO CANYON 2 4566 100 -------------------------------------------------------------------------------- 4 FT CALHOUN 1 4567 100 -------------------------------------------------------------------------------- 4 PALO VERDE 1 4568 100 * -------------------------------------------------------------------------------- 4 PALO VERDE 2 4568 100 -------------------------------------------------------------------------------- 4 PALO VERDE 3 4568 100 -------------------------------------------------------------------------------- 4 RIVER BEND 1 4569 100 -------------------------------------------------------------------------------- 4 SAN ONOFRE 2 4571 001 MODE 2 - STARTUP REPAIRING HIGH PRESSURE TURBINE STEAM LEAK -------------------------------------------------------------------------------- 4 SAN ONOFRE 3 4571 098 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 1 4572 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 2 4572 100 -------------------------------------------------------------------------------- 4 WASHINGTON NUCLEAR 2 4574 006 COND 2 - STARTUP * STARTUP TESTING -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 06/12/95 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 WATERFORD 3 4575 000 06/10 UNK MODE 3 - HOT STANDBY * UE DECLARED OVER THE WEEKEND (SEE #28923). AT 300F, PLACING LTOP's IN SVC. EDG "A" STILL SUPPLYING VITAL LOADS, RUNNING WITHOUT PROBLEMS. OUTLOOK FOR RESTORING "A" SIDE NON- VITAL BUSES APPEAR GOOD. GRID IS STABLE, WEATHER OK. -------------------------------------------------------------------------------- 4 WOLF CREEK 1 4576 100 -------------------------------------------------------------------------------- * - REASON OR COMMENT HAS BEEN CHANGED IN PAST 24 HOURS # - NUMBER OF REACTOR SCRAMS WITHIN PAST 24 HOURS NOTE - REACTOR STATUS DATA COLLECTED BETWEEN 4 A.M. AND 8 A.M. EACH DAY. ALL TIMES ARE BASED ON EASTERN TIMES (ET).