NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 08/30/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 BEAVER VALLEY 1 4501 100 -------------------------------------------------------------------------------- 1 BEAVER VALLEY 2 4501 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 1 4502 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 2 4502 052 LOAD FOLLOWING * -------------------------------------------------------------------------------- 1 FITZPATRICK 1 4503 075 HOLDING DUE TO PRESENT ROD PATTERN CONFIGURATION -------------------------------------------------------------------------------- 1 GINNA 1 4504 098 -------------------------------------------------------------------------------- 1 HADDAM NECK 1 4505 100 -------------------------------------------------------------------------------- 1 HOPE CREEK 1 4506 100 -------------------------------------------------------------------------------- 1 INDIAN POINT 2 4507 090 FUEL CONSERVATION -------------------------------------------------------------------------------- 1 INDIAN POINT 3 4508 000 02/93 UNK MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 LIMERICK 1 4509 100 -------------------------------------------------------------------------------- 1 LIMERICK 2 4509 098 COASTDOWN -------------------------------------------------------------------------------- 1 MAINE YANKEE 1 4510 100 -------------------------------------------------------------------------------- 1 MILLSTONE 1 4511 090 INCREASING REACTOR POWER * TO 96% or 97% (LIMITED IN REACTOR POWER BY CURRENT ROD PATTERN). -------------------------------------------------------------------------------- 1 MILLSTONE 2 4512 000 07/27 08/30 MODE 3 - HOT STANDBY * COMING OUT OF A MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 MILLSTONE 3 4513 100 -------------------------------------------------------------------------------- 1 NINE MILE POINT 1 4514 100 -------------------------------------------------------------------------------- 1 NINE MILE POINT 2 4514 100 -------------------------------------------------------------------------------- 1 OYSTER CREEK 1 4515 100 -------------------------------------------------------------------------------- 1 PEACH BOTTOM 2 4516 073 COASTDOWN TO REFUELING * -------------------------------------------------------------------------------- 1 PEACH BOTTOM 3 4516 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 08/30/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 PILGRIM 1 4517 000 08/29 UNK COND 4 - COLD SHUTDOWN * # REACTOR SCRAM DUE TO MAIN TRANSFORMER LOCKOUT. LICENSEE IS STILL LOOKING FOR THE ROOT CAUSE OF THE MAIN TRANSFORMER LOCKOUT. RESTART DATE UNKNOWN. SEE EVENT # 27720 FOR FURTHER DETAILS. -------------------------------------------------------------------------------- 1 SALEM 1 4518 001 MODE 2 - STARTUP * HOLDING AT THIS POWER LEVEL UNTIL EHC TESTING OF THE MAIN TURBINE IS COMPLETED. -------------------------------------------------------------------------------- 1 SALEM 2 4518 100 -------------------------------------------------------------------------------- 1 SEABROOK 1 4519 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 1 4520 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 2 4520 100 -------------------------------------------------------------------------------- 1 THREE MILE ISLAND 1 4521 100 THEY HAVE THEIR MAIN * TURBINE RUNNING IN MANUAL CONTROL (HAVE BAD CIRCUIT CARD WHICH SUPPLIES SIGNAL TO TURBINE EHC SYSTEM). 08/31/94 BETWEEN 1300 & 1400 HOURS WILL TAKE MAIN TURBINE OFF LINE AND REPLACE DEFECTIVE CARD. -------------------------------------------------------------------------------- 1 VERMONT YANKEE 1 4522 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 08/30/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 BROWNS FERRY 1 4525 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BROWNS FERRY 2 4525 093 COASTDOWN TO REFUELING * -------------------------------------------------------------------------------- 2 BROWNS FERRY 3 4525 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BRUNSWICK 1 4526 100 -------------------------------------------------------------------------------- 2 BRUNSWICK 2 4526 100 -------------------------------------------------------------------------------- 2 CATAWBA 1 4527 100 -------------------------------------------------------------------------------- 2 CATAWBA 2 4527 100 -------------------------------------------------------------------------------- 2 CRYSTAL RIVER 3 4528 100 -------------------------------------------------------------------------------- 2 FARLEY 1 4529 100 -------------------------------------------------------------------------------- 2 FARLEY 2 4529 100 -------------------------------------------------------------------------------- 2 GRAND GULF 1 4530 008 COND 2 - STARTUP * HOLDING POWER LEVEL. REPLACED BEARING # 11 ON MAIN TURBINE & STILL HAD HIGH VIBRATION PROBLEM. TOOK MAIN GENERATOR OFF LINE (BELIEVE THEY HAVE A POSSIBLE ROTOR PROBLEM WHICH CAUSES THE VIBRATION PROBLEM AT 1800rpm). -------------------------------------------------------------------------------- 2 HARRIS 1 4531 100 -------------------------------------------------------------------------------- 2 HATCH 1 4532 100 -------------------------------------------------------------------------------- 2 HATCH 2 4532 100 -------------------------------------------------------------------------------- 2 MCGUIRE 1 4533 000 08/19 10/15 MODE 6 - REFUELING * REFUELING OUTAGE (CORE OFF LOADING IN PROGRESS). -------------------------------------------------------------------------------- 2 MCGUIRE 2 4533 100 2.6 GPD LEAK IN THE 'D' STEAM GENERATOR -------------------------------------------------------------------------------- 2 NORTH ANNA 1 4534 060 COASTDOWN TO REFUELING -------------------------------------------------------------------------------- 2 NORTH ANNA 2 4534 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 08/30/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 OCONEE 1 4535 100 -------------------------------------------------------------------------------- 2 OCONEE 2 4535 100 -------------------------------------------------------------------------------- 2 OCONEE 3 4535 100 -------------------------------------------------------------------------------- 2 ROBINSON 2 4536 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 1 4537 100 -------------------------------------------------------------------------------- 2 SEQUOYAH 2 4537 000 07/04 11/01 MODE 6 - REFUELING REFUELING OUTAGE - - - - DEFUELED -------------------------------------------------------------------------------- 2 ST LUCIE 1 4538 079 HOLDING POWER LEVEL TO * REPAIR EXPANSION JOINT LEAK ON CIRCULATING WATER PUMP & WATER BOX CLEANING IS IN PROGRESS. -------------------------------------------------------------------------------- 2 ST LUCIE 2 4538 100 -------------------------------------------------------------------------------- 2 SUMMER 1 4539 080 COASTDOWN TO REFUELING -------------------------------------------------------------------------------- 2 SURRY 1 4540 100 -------------------------------------------------------------------------------- 2 SURRY 2 4540 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 3 4541 100 -------------------------------------------------------------------------------- 2 TURKEY POINT 4 4541 100 -------------------------------------------------------------------------------- 2 VOGTLE 1 4542 079 COASTDOWN TO REFUELING * (OUTAGE STARTS 09/10/94). -------------------------------------------------------------------------------- 2 VOGTLE 2 4542 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 08/30/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 BIG ROCK POINT 1 4544 077 COASTDOWN TO REFUELING * -------------------------------------------------------------------------------- 3 BRAIDWOOD 1 4545 100 -------------------------------------------------------------------------------- 3 BRAIDWOOD 2 4545 100 -------------------------------------------------------------------------------- 3 BYRON 1 4546 047 COASTDOWN TO REFUELING -------------------------------------------------------------------------------- 3 BYRON 2 4546 067 REPAIRING A CONDENSER * TUBE LEAK. -------------------------------------------------------------------------------- 3 CALLAWAY 1 4547 100 -------------------------------------------------------------------------------- 3 CLINTON 1 4548 100 -------------------------------------------------------------------------------- 3 COOK 1 4549 100 -------------------------------------------------------------------------------- 3 COOK 2 4549 047 COASTDOWN TO REFUELING -------------------------------------------------------------------------------- 3 DAVIS BESSE 1 4550 085 COASTDOWN TO REFUELING * -------------------------------------------------------------------------------- 3 DRESDEN 2 4551 000 08/08 09/24 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 DRESDEN 3 4551 000 08/06 09/20 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 DUANE ARNOLD 1 4552 100 -------------------------------------------------------------------------------- 3 FERMI 2 4553 000 12/93 10/01 COND 5 - REFUELING REFUELING OUTAGE - - - - DEFUELED -------------------------------------------------------------------------------- 3 KEWAUNEE 1 4554 100 -------------------------------------------------------------------------------- 3 LASALLE 1 4555 100 -------------------------------------------------------------------------------- 3 LASALLE 2 4555 010 COND 2 - STARTUP * HOLDING POWER LEVEL. TROUBLESHOOTING EHC PROBLEMS. WHEN IN CHEST WARMING & SHELL WARMING OF THEIR MAIN TURBINE BYPASS VALVE PERIODICALLY OSCILLATES. -------------------------------------------------------------------------------- 3 MONTICELLO 1 4556 084 COASTDOWN TO REFUELING -------------------------------------------------------------------------------- 3 PALISADES 1 4557 100 -------------------------------------------------------------------------------- 3 PERRY 1 4558 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 08/30/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 POINT BEACH 1 4559 100 -------------------------------------------------------------------------------- 3 POINT BEACH 2 4559 100 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 1 4560 100 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 2 4560 100 -------------------------------------------------------------------------------- 3 QUAD CITIES 1 4561 020 HOLDING POWER LEVEL FOR * HOT SCRAM TIMING OF THEIR CONTROL RODS. -------------------------------------------------------------------------------- 3 QUAD CITIES 2 4561 034 RECIRCULATION PUMP "A" * TRIPPED. FOUND CONTROL POWER TRANSFORMER FOR RECIRC PUMP "A" SEVERLY OVERHEATED - INVESTIGATING PROBLEM. FOR EVENT # 27721 REPLACING ONE SCRAM VALVE & REPALCEING SCRAM SOLENOIDS FOR ROD D-11. -------------------------------------------------------------------------------- 3 ZION 1 4562 100 -------------------------------------------------------------------------------- 3 ZION 2 4562 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 08/30/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 ARKANSAS NUCLEAR 1 4563 100 -------------------------------------------------------------------------------- 4 ARKANSAS NUCLEAR 2 4563 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 1 4564 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 2 4564 084 INCREASING POWER TO 90% * WHERE THEY WILL PERFORM CALORIMETRIC TESTING & THEN WILL GO TO 100%. -------------------------------------------------------------------------------- 4 COOPER 1 4565 000 05/25 UNK COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 4 DIABLO CANYON 1 4566 100 -------------------------------------------------------------------------------- 4 DIABLO CANYON 2 4566 100 -------------------------------------------------------------------------------- 4 FT CALHOUN 1 4567 100 -------------------------------------------------------------------------------- 4 PALO VERDE 1 4568 098 -------------------------------------------------------------------------------- 4 PALO VERDE 2 4568 100 -------------------------------------------------------------------------------- 4 PALO VERDE 3 4568 100 -------------------------------------------------------------------------------- 4 RIVER BEND 1 4569 100 -------------------------------------------------------------------------------- 4 SAN ONOFRE 2 4571 098 -------------------------------------------------------------------------------- 4 SAN ONOFRE 3 4571 097 TURBINE COTROL VALVES * ARE FULL OPEN. LIMITED IN POWER DUE TO SEA WATER TEMPERATURE. -------------------------------------------------------------------------------- 4 SOUTH TEXAS 1 4572 100 -------------------------------------------------------------------------------- 4 SOUTH TEXAS 2 4572 100 -------------------------------------------------------------------------------- 4 WASHINGTON NUCLEAR 2 4574 100 -------------------------------------------------------------------------------- 4 WATERFORD 3 4575 100 -------------------------------------------------------------------------------- 4 WOLF CREEK 1 4576 093 COASTDOWN TO REFUELING -------------------------------------------------------------------------------- * - REASON OR COMMENT HAS BEEN CHANGED IN PAST 24 HOURS # - NUMBER OF REACTOR SCRAMS WITHIN PAST 24 HOURS NOTE - REACTOR STATUS DATA COLLECTED BETWEEN 4 A.M. AND 8 A.M. EACH DAY. ALL TIMES ARE BASED ON EASTERN TIMES (ET).