NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 04/06/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 BEAVER VALLEY 1 2201 100 -------------------------------------------------------------------------------- 1 BEAVER VALLEY 2 2201 100 -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 1 2202 000 02/09 05/13 MODE 6 - REFUELING * CORE RELOAD COMPLETE, MAKING PREPS TO COUPLE CEA's -------------------------------------------------------------------------------- 1 CALVERT CLIFFS 2 2202 100 -------------------------------------------------------------------------------- 1 FITZPATRICK 1 2203 000 04/03 04/28 COND 4 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 GINNA 1 2204 000 03/04 04/11 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 1 HADDAM NECK 1 2205 100 -------------------------------------------------------------------------------- 1 HOPE CREEK 1 2206 000 03/04 04/22 COND 5 - REFUELING * REFUELING OUTAGE- SHUTDOWN COOLING ISOLATED WHEN A PRESSURE DETECTOR TRIPPED ON HIGH PRESSURE (DETECTOR WAS ISOLATED FOR MAINTENANCE). SEE #27045. -------------------------------------------------------------------------------- 1 INDIAN POINT 2 2207 090 REDUCED POWER DUE TO A SG TUBE LEAK. LEAK RATE <.01 GPM -------------------------------------------------------------------------------- 1 INDIAN POINT 3 2208 000 02/93 10/01 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 1 LIMERICK 1 2209 100 -------------------------------------------------------------------------------- 1 LIMERICK 2 2209 100 -------------------------------------------------------------------------------- 1 MAINE YANKEE 1 2210 100 -------------------------------------------------------------------------------- 1 MILLSTONE 1 2211 000 01/15 04/13 COND 4 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 1 MILLSTONE 2 2211 100 HAVE A LOWER FAILED SEAL ON RCP "D" (LESS THAN 500psid ACROSS THE SEAL). -------------------------------------------------------------------------------- 1 MILLSTONE 3 2212 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 04/06/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 1 NINE MILE POINT 1 2213 000 04/05 04/09 COND 4 - COLD SHUTDOWN * # RX SCRAM ON A GENERATOR LOAD REJECT. SEE #27041. -------------------------------------------------------------------------------- 1 NINE MILE POINT 2 2213 100 -------------------------------------------------------------------------------- 1 OYSTER CREEK 1 2215 000 04/05 04/08 COND 4 - COLD SHUTDOWN * # RX SCRAM FOLLOWING A TURBINE TRIP CAUSED BY HIGH REACTOR VESSEL WATER LEVEL TRANSIENT. SEE #27043. -------------------------------------------------------------------------------- 1 PEACH BOTTOM 2 2216 100 -------------------------------------------------------------------------------- 1 PEACH BOTTOM 3 2216 100 -------------------------------------------------------------------------------- 1 PILGRIM 1 2217 100 -------------------------------------------------------------------------------- 1 SALEM 1 2218 075 REDUCED POWER DUE TO * GRASS PROBLEMS ON THE DELAWARE RIVER. -------------------------------------------------------------------------------- 1 SALEM 2 2218 072 REDUCED POWER DUE TO * GRASS PROBLEMS ON THE DELAWARE RIVER. -------------------------------------------------------------------------------- 1 SEABROOK 1 2219 092 * -------------------------------------------------------------------------------- 1 SUSQUEHANNA 1 2221 100 -------------------------------------------------------------------------------- 1 SUSQUEHANNA 2 2221 000 03/14 05/20 COND 5 - REFUELING REFUELING OUTAGE- UNLOADING CORE -------------------------------------------------------------------------------- 1 THREE MILE ISLAND 1 2222 100 -------------------------------------------------------------------------------- 1 VERMONT YANKEE 1 2224 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 04/06/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 BROWNS FERRY 1 2229 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BROWNS FERRY 2 2229 100 -------------------------------------------------------------------------------- 2 BROWNS FERRY 3 2229 000 03/85 UNK COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 BRUNSWICK 1 2230 100 -------------------------------------------------------------------------------- 2 BRUNSWICK 2 2230 000 03/26 06/28 COND 5 - REFUELING REFUELING OUTAGE - CORE OFF LOAD IN PROGRESS -------------------------------------------------------------------------------- 2 CATAWBA 1 2231 100 -------------------------------------------------------------------------------- 2 CATAWBA 2 2231 100 -------------------------------------------------------------------------------- 2 CRYSTAL RIVER 3 2233 078 HOLDING AFTER REMOVING WATERBOX FROM SERVICE - WILL ENTER OUTAGE ON 4/7. -------------------------------------------------------------------------------- 2 FARLEY 1 2234 000 03/04 04/28 MODE 6 - REFUELING * REFUELING OUTAGE - CORE RELOAD COMPLETE -------------------------------------------------------------------------------- 2 FARLEY 2 2234 099 -------------------------------------------------------------------------------- 2 GRAND GULF 1 2235 073 WILL BE INCREASING POWER * TO 100% -------------------------------------------------------------------------------- 2 HARRIS 1 2236 000 03/18 05/02 MODE 6 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 HATCH 1 2237 100 -------------------------------------------------------------------------------- 2 HATCH 2 2237 000 03/16 04/28 COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 2 MCGUIRE 1 2239 100 -------------------------------------------------------------------------------- 2 MCGUIRE 2 2239 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 1 2240 100 -------------------------------------------------------------------------------- 2 NORTH ANNA 2 2240 100 * -------------------------------------------------------------------------------- 2 OCONEE 1 2241 100 -------------------------------------------------------------------------------- 2 OCONEE 2 2241 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 04/06/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 2 OCONEE 3 2241 100 -------------------------------------------------------------------------------- 2 ROBINSON 2 2242 050 HOLDING FOR A * CALORIMETRIC -------------------------------------------------------------------------------- 2 SEQUOYAH 1 2243 000 03/93 UNK MODE 3 - HOT STANDBY * RCS PRESSURE CURRENTLY 2220 PSI WITH NO PZR SAFETY VALVE (#68565) LEAKAGE - MANAGEMENT MEETING WILL DISCUSS WHETHER TO COOLDOWN FOR REPAIRS -------------------------------------------------------------------------------- 2 SEQUOYAH 2 2243 100 -------------------------------------------------------------------------------- 2 ST LUCIE 1 2244 100 * -------------------------------------------------------------------------------- 2 ST LUCIE 2 2244 000 02/13 04/10 MODE 5 - COLD SHUTDOWN PREPARING FOR HEATUP -------------------------------------------------------------------------------- 2 SUMMER 1 2245 065 FUEL CONSERVATION -------------------------------------------------------------------------------- 2 SURRY 1 2246 100 * -------------------------------------------------------------------------------- 2 SURRY 2 2246 094 * -------------------------------------------------------------------------------- 2 TURKEY POINT 3 2247 000 04/03 05/19 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 2 TURKEY POINT 4 2247 100 -------------------------------------------------------------------------------- 2 VOGTLE 1 2248 100 -------------------------------------------------------------------------------- 2 VOGTLE 2 2248 096 INCREASING POWER * -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 04/06/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 BIG ROCK POINT 1 2250 000 04/04 04/13 COND 4 - COLD SHUTDOWN * MAINTENANCE OUTAGE - SHUTDOWN TO REPAIR STEAM LEAKS -------------------------------------------------------------------------------- 3 BRAIDWOOD 1 2251 000 03/03 04/27 MODE 6 - REFUELING CORE RELOAD COMPLETED -------------------------------------------------------------------------------- 3 BRAIDWOOD 2 2251 000 04/05 UNK MODE 3 - HOT STANDBY * # RX TRIP FOLLOWING A TRANSFORMER FAULT- ONE ROD STUCK AT 210 STEPS. #27046 -------------------------------------------------------------------------------- 3 BYRON 1 2252 099 -------------------------------------------------------------------------------- 3 BYRON 2 2252 099 -------------------------------------------------------------------------------- 3 CALLAWAY 1 2253 100 -------------------------------------------------------------------------------- 3 CLINTON 1 2270 100 -------------------------------------------------------------------------------- 3 COOK 1 2254 000 02/12 04/19 MODE 6 - REFUELING * CORE RELOAD COMPLETE, PREPARING TO PUT THE HEAD ON. -------------------------------------------------------------------------------- 3 COOK 2 2254 000 03/06 04/22 MODE 4 - HOT SHUTDOWN -------------------------------------------------------------------------------- 3 DAVIS BESSE 1 2255 100 -------------------------------------------------------------------------------- 3 DRESDEN 2 2256 099 * -------------------------------------------------------------------------------- 3 DRESDEN 3 2256 000 03/10 05/30 COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 3 DUANE ARNOLD 1 2257 100 -------------------------------------------------------------------------------- 3 FERMI 2 2258 000 12/93 10/01 COND 4 - COLD SHUTDOWN LP TURBINE MAINTENANCE -------------------------------------------------------------------------------- 3 KEWAUNEE 1 2259 000 04/01 05/06 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 3 LASALLE 1 2261 000 02/18 06/01 COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 3 LASALLE 2 2261 095 * -------------------------------------------------------------------------------- 3 MONTICELLO 1 2263 100 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 04/06/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 3 PALISADES 1 2264 000 02/17 04/19 MODE 5 - COLD SHUTDOWN MAINTENANCE OUTAGE -------------------------------------------------------------------------------- 3 PERRY 1 2265 000 02/06 05/26 COND 5 - REFUELING DEFUELED -------------------------------------------------------------------------------- 3 POINT BEACH 1 2266 000 04/01 05/01 MODE 5 - COLD SHUTDOWN REFUELING OUTAGE -------------------------------------------------------------------------------- 3 POINT BEACH 2 2266 099 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 1 2267 100 -------------------------------------------------------------------------------- 3 PRAIRIE ISLAND 2 2267 100 -------------------------------------------------------------------------------- 3 QUAD CITIES 1 2268 000 03/13 07/03 COND 5 - REFUELING * REFUELING OUTAGE- CORE OFF-LOADED -------------------------------------------------------------------------------- 3 QUAD CITIES 2 2268 097 LIMITED TO 97% -------------------------------------------------------------------------------- 3 ZION 1 2269 000 04/03 UNK MODE 4 - HOT SHUTDOWN MAINTENANCE OUTAGE - WILL INSPECT GENERATOR INTERNALLY FOR COMBUSTION PRODUCTS - REPLACING "1W" MAIN XFMR (REQUIRES APPROX 2 WKS) -------------------------------------------------------------------------------- 3 ZION 2 2269 000 10/93 UNK MODE 3 - HOT STANDBY RESTART ON HOLD PENDING ROOT CAUSE INVESTIGATION FOR UNIT 1 -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 04/06/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 ARKANSAS NUCLEAR 1 2271 100 -------------------------------------------------------------------------------- 4 ARKANSAS NUCLEAR 2 2271 000 03/11 04/28 MODE 6 - REFUELING REFUELING OUTAGE - CORE RELOAD COMPLETED -------------------------------------------------------------------------------- 4 COMANCHE PEAK 1 2272 100 -------------------------------------------------------------------------------- 4 COMANCHE PEAK 2 2272 073 LIMITED TO 73% -------------------------------------------------------------------------------- 4 COOPER 1 2273 100 -------------------------------------------------------------------------------- 4 DIABLO CANYON 1 2281 000 03/11 05/10 MODE 6 - REFUELING DEFUELED -------------------------------------------------------------------------------- 4 DIABLO CANYON 2 2281 000 03/28 04/09 MODE 5 - COLD SHUTDOWN * -------------------------------------------------------------------------------- 4 FT CALHOUN 1 2274 100 -------------------------------------------------------------------------------- 4 PALO VERDE 1 2282 086 ADMIN LIMIT OF 86% POWER DUE TO STRESS CORROSION IN THE STEAM GENERATORS. -------------------------------------------------------------------------------- 4 PALO VERDE 2 2283 086 ADMIN LIMIT OF 86% POWER DUE TO STRESS CORROSION IN THE STEAM GENERATORS. -------------------------------------------------------------------------------- 4 PALO VERDE 3 2284 000 03/18 05/28 MODE 6 - REFUELING REFUELING OUTAGE - DEFUELED -------------------------------------------------------------------------------- 4 RIVER BEND 1 2276 098 COASTDOWN TO REFUELING -------------------------------------------------------------------------------- 4 SAN ONOFRE 2 2287 098 OPERATING AT A LOWER COLD LEG TEMPERATURE TO INCREASE STEAM GENERATOR TUBE LIFE. -------------------------------------------------------------------------------- 4 SAN ONOFRE 3 2287 096 OPERATING AT A LOWER * COLD LEG TEMPERATURE TO INCREASE STEAM GENERATOR TUBE LIFE. -------------------------------------------------------------------------------- 4 SOUTH TEXAS 1 2277 090 PREPARING FOR FLUX MAP * -------------------------------------------------------------------------------- 4 SOUTH TEXAS 2 2277 000 02/93 05/22 MODE 6 - REFUELING CORE RELOAD COMPLETED -------------------------------------------------------------------------------- 4 WASHINGTON NUCLEAR 2 2289 065 PERFORMING SCRAM TIME * TESTING AFTER REBUILDING SCRAM PILOT VALVES -------------------------------------------------------------------------------- NRC OPERATIONS CENTER PLANT STATUS REPORT FOR 04/06/94 UNEVALUATED INFORMATION PROVIDED BY THE FACILITY ------------------------------------------------ REG PLANT NAME PHONE %PWR DOWN RESTART REASON OR COMMENT * # --- --------------------- ----- ---- ----- ------- ------------------------ - - 4 WATERFORD 3 2278 000 03/04 04/18 MODE 5 - COLD SHUTDOWN * -------------------------------------------------------------------------------- 4 WOLF CREEK 1 2279 100 -------------------------------------------------------------------------------- * - REASON OR COMMENT HAS BEEN CHANGED IN PAST 24 HOURS # - NUMBER OF REACTOR SCRAMS WITHIN PAST 24 HOURS NOTE - REACTOR STATUS DATA COLLECTED BETWEEN 4 A.M. AND 8 A.M. EACH DAY. ALL TIMES ARE BASED ON EASTERN TIMES (ET).