U.S. Nuclear Regulatory Commission Operations Center Event Reports For 12/22/1998 - 12/23/1998 ** EVENT NUMBERS ** 35179 35180 35184 35185 35186 35187 35188 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35179 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: MCGUIRE REGION: 2 |NOTIFICATION DATE: 12/20/1998| | UNIT: [] [2] [] STATE: NC |NOTIFICATION TIME: 10:56[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 12/20/1998| +------------------------------------------------+EVENT TIME: 09:56[EST]| | NRC NOTIFIED BY: YODER |LAST UPDATE DATE: 12/22/1998| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |PAUL FREDRICKSON R2 | |10 CFR SECTION: | | |AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | | |NLCO TECH SPEC LCO A/S | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE LICENSEE DECLARED BOTH TRAINS OF ANNULUS VENTILATION INOPERABLE AND | | ENTERED T.S. 3.0.3 LCO ACTION STATEMENT. | | | | BOTH TRAINS OF ANNULUS VENTILATION WERE INOPERABLE DUE TO COMPENSATORY | | ACTIONS NOT TAKEN WHEN ANNULUS DOORS WERE OPENED FOR ENTRY INTO THE ANNULUS. | | COMPENSATORY ACTIONS REQUIRE SECURITY TO STAND-BY AND NOTIFY THE CONTROL | | ROOM WHEN THE DOORS ARE OPENED. SECURITY WAS IN FACT STANDING BY THE DOORS, | | BUT THE CONTROL ROOM WAS NOT NOTIFIED WHILE THE ENTRY WAS MADE. THE CONTROL | | ROOM IS REQUIRED TO NOTIFY SECURITY TO CLOSE THE DOORS IN THE EVENT OF AN | | ANNULUS VENTILATION SYSTEM ACTUATION. THE LICENSEE HAS EXITED T.S. 3.0.3 | | ACTION STATEMENT. | | THE RESIDENT INSPECTOR WILL BE NOTIFIED OF THE EVENT. | | | | ***RETRACTION OF EVENT ON 12/22/98 AT 1417ET BY HUFFEY TAKEN BY | | MACKINNON*** | | | | THE BASIS OF THIS RETRACTION IS THAT SUBSEQUENT EVALUATION OF THE | | REQUIREMENTS OF THE NEWLY IMPLEMENTED IMPROVED TECHNICAL SPECIFICATION | | 3.6.10 FOR ANNULUS VENTILATION SYSTEM AND 3.6.16 FOR THE REACTOR BUILDING | | INDICATES THAT THE ANNULUS VENTILATION SYSTEM WAS OPERABLE. THE ANNULUS | | DOORS WERE OPENED FOR NORMAL TRANSIT ENTRY AND EXIT ON 12/20/98. TECHNICAL | | SPECIFICATION 3.6.16 ALLOWS THE DOORS TO BE OPENED FOR NORMAL TRANSIT ENTRY | | AND EXIT WITHOUT ANY COMPENSATORY MEASURES. TECHNICAL SPECIFICATION 3.6.16 | | ALSO ALLOWS 24 HOURS FOR RETURNING THE INOPERABLE REACTOR BUILDING TO | | OPERABLE STATUS. COMPENSATORY MEASURES FOR OPERABILITY OF ANNULUS | | VENTILATION FOR ANNULUS DOORS ARE ACTUALLY ONLY REQUIRED DURING NON-ROUTINE | | ENTRIES. THESE ARE CONDITIONS WHERE THE DOORS MAY BE HELD OPEN FOR AN | | EXTENDED PERIOD OF TIME. COMPENSATORY MEASURES ARE NEEDED TO ENSURE THE | | DOORS WILL BE CLOSED IN RESPONSE TO A DESIGN BASES EVENT. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. THE NRC OPERATIONS | | OFFICER NOTIFIED THE R2DO PIERCE SKINNER. | +------------------------------------------------------------------------------+ !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35180 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: MONTICELLO REGION: 3 |NOTIFICATION DATE: 12/20/1998| | UNIT: [1] [] [] STATE: MN |NOTIFICATION TIME: 18:25[EST]| | RXTYPE: [1] GE-3 |EVENT DATE: 12/20/1998| +------------------------------------------------+EVENT TIME: 16:35[CST]| | NRC NOTIFIED BY: KEVIN PEDERSON |LAST UPDATE DATE: 12/22/1998| | HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |JOHN JACOBSON R3 | |10 CFR SECTION: | | |ASHU 50.72(b)(1)(i)(A) PLANT S/D REQD BY TS | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | UNIT SHUTDOWN REQUIRED BY TECHNICAL SPECIFICATIONS | | | | "Battery charger D-13 shows no load. This battery charger supplies charging | | to the Division I 24-volt battery system. This places the unit in a 24-hour | | Technical Specification required shutdown per T.S. 3.9.B. Engineering is | | evaluating the status of charger D-13." | | | | The NRC Resident Inspector has been informed of this event by the licensee. | | | | * * * Update at 2201 on 12/20/98 from Walsh to Stransky * * * | | | | The battery charger has been repaired, and the shutdown has been terminated. | | Reactor power remained at 100% throughout this event. | | | | The NRC Resident Inspector has been informed by the licensee. The NRC | | Operations Officer notified R3DO John Jacobson. | | | | * * * Update at 0955 on 12/22/98 from Cox to Gould * * * | | | | The 24 VDC battery charger D-13 was declared inoperable at 1635 on 12/20/98 | | and returned to service at 2038. The 24-hour LCO per Technical | | Specification 3.9.8 was exited at 2038. All loads on the 24 VDC batteries | | remained operable. Plant shutdown was never initiated and therefore this | | event is retracted. | | | | The NRC Resident Inspector was notified of this event retraction by the | | licensee. The NRC Operations Officer notified R3DO John Madera. | +------------------------------------------------------------------------------+ !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35184 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PRAIRIE ISLAND REGION: 3 |NOTIFICATION DATE: 12/21/1998| | UNIT: [1] [2] [] STATE: MN |NOTIFICATION TIME: 22:26[EST]| | RXTYPE: [1] W-2-LP,[2] W-2-LP |EVENT DATE: 12/21/1998| +------------------------------------------------+EVENT TIME: 08:04[CST]| | NRC NOTIFIED BY: ANDREWS/BANGASSER |LAST UPDATE DATE: 12/22/1998| | HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |JOHN MADERA R3 | |10 CFR SECTION: | | |DDDD 73.71 UNSPECIFIED PARAGRAPH | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N N 0 Cold Shutdown |0 Cold Shutdown | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - PLANT SECURITY EVENT - | | | | INADEQUATE COMPENSATORY MEASURES TAKEN IN RESPONSE TO SECURITY EVENT. | | IMMEDIATE CORRECT COMPENSATORY MEASURES TAKEN UPON DISCOVERY, REFER TO THE | | HOO LOG FOR ADDITIONAL DETAILS. | | | | THE LICENSEE WILL INFORM THE NRC RESIDENT INSPECTOR. | | | | * * * UPDATE AT 1426 ON 12/22/98 BY PAT RYAN TO JOLLIFFE * * * | | | | UNAUTHORIZED OR UNDETECTED ACCESS TO THE PLANT PROTECTED AREA COULD NOT HAVE | | BEEN GAINED DURING THIS EVENT. THUS, THIS EVENT IS NOT REPORTABLE TO THE | | NRC AND THE LICENSEE DESIRES TO RETRACT THIS EVENT AND DOWNGRADE IT FROM A | | REPORTABLE ONE HOUR SECURITY EVENT TO A LOGGABLE SECURITY EVENT. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | | | | THE NRC OPERATIONS OFFICER NOTIFIED THE R3DO JOHN MADERA. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35185 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: SEABROOK REGION: 1 |NOTIFICATION DATE: 12/22/1998| | UNIT: [1] [] [] STATE: NH |NOTIFICATION TIME: 09:25[EST]| | RXTYPE: [1] W-4-LP |EVENT DATE: 12/22/1998| +------------------------------------------------+EVENT TIME: 08:27[EST]| | NRC NOTIFIED BY: FREEMAN |LAST UPDATE DATE: 12/22/1998| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |JOHN WHITE R1 | |10 CFR SECTION: | | |ARPS 50.72(b)(2)(ii) RPS ACTUATION | | |AESF 50.72(b)(2)(ii) ESF ACTUATION | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 A/R Y 100 Power Operation |0 Hot Standby | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | REACTOR TRIP FROM 100% POWER DUE TO A MAIN TURBINE TRIP. | | | | ON 12/22/98 AT 0827 THE PLANT EXPERIENCED A REACTOR TRIP DUE TO THE 345 KV | | BREAKER 163+11 OPENING, WHICH RESULTED IN A TURBINE TRIP FOLLOWED BY THE | | REACTOR TRIP. THE CAUSE IS BEING INVESTIGATED. THE PLANT ALSO HAD AN | | EMERGENCY FEEDWATER ACTUATION AS DESIGNED ON STEAM GENERATOR LO-LO LEVELS. | | A PRESSURIZER PORV OPENED(APPEARS ONLY ONE OPENED) AND RESEATED. BUS 4 4160 | | VOLT DID NOT AUTO TRANSFER TO THE RESERVE AUXILIARY TRANSFORMER AS DESIGNED. | | THE CAUSE OF THIS FAILURE IS UNKNOWN AND BEING INVESTIGATED. ALL RODS FULLY | | INSERTED AND NO ECCS ACTUATED. THE PLANT IS IN MODE 3 AND RCS PRESSURE IS | | 2238 LBS. AND TEMPERATURE AT 557þF. BUS 4 STARTUP FEED PUMP DID NOT START | | DUE TO LOSS OF POWER ON BUS 4. | | | | THE LICENSEE WILL MAKE A PRESS RELEASE. | | | | THE RESIDENT WAS NOTIFIED. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 35186 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PADUCAH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 12/22/1998| | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 12:49[EST]| | COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 12/21/1998| | 6903 ROCKLEDGE DRIVE |EVENT TIME: 14:30[CST]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 12/22/1998| | CITY: PADUCAH REGION: 3 +-----------------------------+ | COUNTY: McCRACKEN STATE: KY |PERSON ORGANIZATION | |LICENSE#: GDP-1 AGREEMENT: Y |JOHN MADERA R3 | | DOCKET: 0707001 |FREDERICK COMBS NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: BILL HALICKS | | | HQ OPS OFFICER: DICK JOLLIFFE | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NBNL RESPONSE-BULLETIN | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - NRC BULLETIN 91-01, 24 HOUR REPORT - | | | | AT 1430 CST ON 12/21/98, THE LICENSEE DISCOVERED THAT THREE PIECES OF PIPING | | (~3 INCHES DIAMETER X 3 FEET LONG) REMOVED IN THE C-310 BUILDING UNDER | | EQUIPMENT REMOVAL NUCLEAR CRITICALITY SAFETY APPROVAL (NCSA) GEN-10, AND | | CLASSIFIED AS "UNCOMPLICATED HANDLING" (UH) , WERE PLACED IN A TRASH | | DUMPSTER IN VIOLATION OF WASTE HANDLING NCSA GEN-15. NCSA GEN-15 REQUIRES | | THAT FISSILE/POTENTIAL FISSILE WASTE BE ACCUMULATED IN A MAXIMUM 5.5 GALLON | | WASTE DRUM. THE ONLY EXCEPTION TO THIS REQUIREMENT IS IF THE WASTE IS | | EXCEPTED FROM NCS CONTROLS IN ACCORDANCE WITH REQUIREMENT 2 OF NCSA GEN-15. | | THE THREE PIECES OF PIPING WERE NOT EXEMPTED PRIOR TO DISPOSAL. THE | | DUMPSTER WAS THEN TRANSPORTED FROM BUILDING C-310 TO BUILDING C-754 | | VIOLATING THE NCSA GEN-10 TRANSPORTATION REQUIREMENTS WHICH REQUIRE THAT A | | MAXIMUM OF TWO UH ITEMS BE TRANSPORTED PER VEHICLE. THEREFORE, THE IMPROPER | | TRANSPORTATION OF THE THREE ITEMS ALSO RESULTED IN A VIOLATION OF NCSA | | GEN-10. | | | | DOUBLE CONTINGENCY FOR THIS OPERATION RELIES ON THE CONTROLLED PARAMETERS | | GEOMETRY AND INTERACTION. THIS VIOLATION RESULTED IN THE LOSS OF GEOMETRY | | CONTROL. INTERACTION CONTROL WAS MAINTAINED THROUGHOUT THIS INCIDENT. | | | | THE FIRST LEG OF DOUBLE CONTINGENCY RELIES ON INTERACTION BETWEEN | | NCS-APPROVED WASTE CONTAINERS. NCSA GEN-15 REQUIRES A MINIMUM TWO FEET | | EDGE-TO-EDGE SPACING BETWEEN WASTE CONTAINERS TO LIMIT INTERACTION. THIS | | CONTROL WAS NOT MAINTAINED BECAUSE AN UNAPPROVED CONTAINER (TRASH DUMPSTER) | | WAS USED AND THE NEED TO MAINTAIN SPACING WAS NOT IDENTIFIED. NO OTHER | | FISSILE MATERIAL WAS LOCATED NEAR THE DUMPSTER SO THE INTERACTION PROCESS | | CONDITION WAS MAINTAINED. THE SECOND LEG OF DOUBLE CONTINGENCY RELIES ON | | THE USE OF A PROPER GEOMETRY CONTAINER FOR THE GENERATION OF POTENTIAL | | FISSILE WASTE. THIS IS CONTROLLED BY THE REQUIREMENT TO GENERATE WASTE IN A | | 5.5 GALLON WASTE DRUM. GENERATION OF POTENTIAL FISSILE WASTE IN THE | | DUMPSTER VIOLATES THIS CONTROL. SINCE THE THREE PIECES OF EQUIPMENT WERE | | PLACED INTO A TRASH DUMPSTER INSTEAD OF A MAXIMUM 5.5 GALLON WASTE DRUM, THE | | CONTROL WAS VIOLATED AND THE GEOMETRY PROCESS CONDITION WAS NOT MAINTAINED. | | SINCE THE GEOMETRY PROCESS CONDITION WAS EXCEEDED, DOUBLE CONTINGENCY WAS | | NOT MAINTAINED. | | | | A VISUAL INSPECTION OF THE THREE PIECES OF PIPING INDICATED THAT THERE WAS | | VERY LITTLE, IF ANY, FISSILE MATERIAL PRESENT. EACH OF THE THREE ITEMS WAS | | CLASSIFIED AS CONTAINING LESS THAN FIVE POUNDS TOTAL URANIUM IN ACCORDANCE | | WITH NCSA GEN-10. THE THREE ITEMS TOGETHER CONTAINED LESS THAN 15 POUNDS | | URANIUM. THIS IS 40 TIMES LESS THAN THE AMOUNT NEEDED FOR A CRITICALITY TO | | BE POSSIBLE. THEREFORE, A CRITICALITY WAS NOT POSSIBLE. | | | | NUCLEAR CRITICALLY SAFETY ENGINEERS EVALUATED THE INCIDENT AND DIRECTED THAT | | THE MATERIAL INVOLVED BE REMOVED FROM THE UNAPPROVED WASTE CONTAINER AND | | TRANSPORTED TO THE C-400 FACILITY WHERE CRITICALITY ACCIDENT ALARM SYSTEM | | COVERAGE IS OPERABLE AND PLACED IN PROPER STORAGE. THIS RELOCATION WAS | | COMPLETED AT 2211 CST ON 12/21/98. | | | | THIS EVENT IS SUBMITTED IN ACCORDANCE WITH SAFETY ANALYSIS REPORT TABLE | | 6.9-1, CRITERIA A.4.a AS AN NRC BULLETIN 91-01, SUPPLEMENT 1, 24-REPORT. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35187 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PALISADES REGION: 3 |NOTIFICATION DATE: 12/22/1998| | UNIT: [1] [] [] STATE: MI |NOTIFICATION TIME: 14:47[EST]| | RXTYPE: [1] CE |EVENT DATE: 12/22/1998| +------------------------------------------------+EVENT TIME: 11:43[EST]| | NRC NOTIFIED BY: DAN MALONE |LAST UPDATE DATE: 12/22/1998| | HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |JOHN MADERA R3 | |10 CFR SECTION: | | |AESF 50.72(b)(2)(ii) ESF ACTUATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Cold Shutdown |0 Cold Shutdown | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - EDGs AUTO STARTED & LOADED DUE TO FAILED SAFEGUARDS XFORMER AUTO TAP | | CHANGER - | | | | AT 1143 CST ON 12/22/98, DURING PLANT HEATUP, THE SAFEGUARDS TRANSFORMER | | AUTOMATIC TAP CHANGER APPARENTLY FAILED AND CAUSED VOLTAGE TO BE LOWERED ON | | BOTH 2400 VOLT SAFETY BUSES #1C AND #1D. THE REDUCED VOLTAGE CAUSED BOTH | | EMERGENCY DIESEL GENERATORS (EDGs) TO AUTOMATICALLY START AND LOAD BUSES #1C | | AND #1D. POWER ON BUSES #1C AND #1D HAS SUBSEQUENTLY BEEN TRANSFERRED FROM | | THE EDGs TO THE ALTERNATE OFFSITE POWER SUPPLY. THE EDGs HAVE BEEN | | SECURED. | | | | THE LICENSEE IS INVESTIGATING THE CAUSE AND DETERMINING CORRECTIVE ACTIONS. | | | | THE PLANT IS STABLE IN PRE-EVENT CONDITIONS. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 35188 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: MS DIV OF RADIOLOGICAL HEALTH |NOTIFICATION DATE: 12/22/1998| |LICENSEE: BURNS COOLEY DENNIS, INC |NOTIFICATION TIME: 15:44[EST]| | CITY: JACKSON REGION: 2 |EVENT DATE: 12/22/1998| | COUNTY: STATE: MS |EVENT TIME: 13:30[CST]| |LICENSE#: MS-619-01 AGREEMENT: Y |LAST UPDATE DATE: 12/22/1998| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |PIERCE SKINNER R2 | | | | +------------------------------------------------+ | | NRC NOTIFIED BY: BOB NELSON, MS DRH | | | HQ OPS OFFICER: DICK JOLLIFFE | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - TROXLER MOISTURE DENSITY GAUGE FELL FROM A MOVING PICKUP TRUCK IN JACKSON, | | MS - | | | | A TROXLER MOISTURE DENSITY GAUGE INSIDE ITS LARGE RECTANGULAR YELLOW PLASTIC | | TRANSPORT CASE WITH 8 MILLICURIES Cs-137 AND 40 MILLICURIES Am-241-Be | | SOURCES INTACT (MODEL #3411-B, SERIAL #9955) FELL FROM A MOVING PICKUP TRUCK | | IN THE VICINITY OF NORTHSIDE DRIVE IN NORTH JACKSON, MS. | | | | A REPRESENTATIVE OF BURNS COOLEY DENNIS, INC, THE OWNER OF THE 50 - 60 POUND | | GAUGE, NOTIFIED THE HINDS AND RIDGELAND COUNTY POLICE AND THE MISSISSIPPI | | EMERGENCY MANAGEMENT AGENCY (MEMA). THE OWNER IS OFFERING A $250 REWARD FOR | | THE RETURN OF THE GAUGE. MEMA IS PLANNING TO ISSUE A PRESS RELEASE. | +------------------------------------------------------------------------------+