U.S. Nuclear Regulatory Commission Operations Center Event Reports For 04/29/98 - 04/30/98 ** EVENT NUMBERS ** 34038 34147 34148 34149 34150 34151 34152 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 34038 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: HATCH REGION: 2 |NOTIFICATION DATE: 04/08/98 | |UNIT: [1] [2] [ ] STATE: GA |NOTIFICATION TIME: 20:19 [ET]| |RX TYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 04/08/98 | +------------------------------------------------+EVENT TIME: 16:33[EDT]| |NRC NOTIFIED BY: BARNES |LAST UPDATE DATE: 04/29/98 | |HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |PIERCE SKINNER RDO | |AINC 50.72(b)(2)(iii)(C) POT UNCNTRL RAD REL | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | 2 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | NONCONSERVATIVE RADIATION MONITOR SETPOINTS FOUND DURING CALIBRATION. | | | | WHILE PERFORMING A CALIBRATION OF THE REACTOR BUILDING VENTILATION EXHAUST | | RADIATION MONITORS, TWO OF THE MONITORS WERE FOUND WITH NONCONSERVATIVE | | SETPOINTS. RADIATION MONITOR 1D11-K609A WAS SET TO TRIP AT 55 mR/HR, WHILE | | MONITOR 1D11-K609C WAS SET TO TRIP AT 51 mR/HR. THE TECHNICAL | | SPECIFICATION (TS) SETPOINT LIMIT FOR THESE MONITORS IS 20 mR/HR. | | | | THE LICENSEE STATED THIS CONDITION WOULD HAVE RESULTED IN DELAYED REACTOR | | BUILDING VENTILATION ISOLATION, PCIS GROUP 2 ISOLATION, AND AUTOMATIC | | ACTUATION OF THE STANDBY GAS TREATMENT SYSTEM. THE LICENSEE HAS | | RECALIBRATED THE SETPOINTS TO WITHIN TS LIMITS. THE NRC RESIDENT INSPECTOR | | WILL BE INFORMED. | | | | * * * UPDATE AT 1626 ON 04/29/98 BY DISMUKES TAKEN BY MACKINNON * * * | | | | THE AS-FOUND ACTUATION SETPOINTS FOR RADIATION MONITORS 1D11-K609A AND | | 1D11-K609C WERE 55 mR/HR AND 51 mR/HR, RESPECTIVELY. ASSUMING A SINGLE | | POINT FAILURE, THE MONITORS WOULD HAVE PERFORMED THEIR SAFETY FUNCTION WELL | | BEFORE THE OFFSITE DOSE LIMITS EXCEEDED 25% OF THE 10CFR100 LIMITS PER | | CALCULATIONS PERFORMED BY ARCHITECT/ENGINEER. THE 25% OF 10CFR100 LIMITS | | IS THE LICENSING LIMIT. THEREFORE, THE LICENSEE DESIRES TO RETRACT THIS | | EVENT NOTIFICATION. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. THE NRC OPERATIONS | | OFFICER NOTIFIED THE R2DO PIERCE SKINNER. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 34147 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: NORTH ANNA REGION: 2 |NOTIFICATION DATE: 04/29/98 | |UNIT: [1] [2] [ ] STATE: VA |NOTIFICATION TIME: 02:55 [ET]| |RX TYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 04/29/98 | +------------------------------------------------+EVENT TIME: 01:45[EDT]| |NRC NOTIFIED BY: JIM JOHNSTONE |LAST UPDATE DATE: 04/29/98 | |HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |PIERCE SKINNER RDO | |APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | 2 | N N 0 COLD SHUTDOWN | 0 COLD SHUTDOWN | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - NORTH ANNA EARLY WARNING SYSTEM INADVERTENTLY ACTIVATED - | | | | AT 0040 ON 04/29/98, THE NORTH ANNA EARLY WARNING SYSTEM WAS INADVERTENTLY | | ACTIVATED BY THE LOUISA COUNTY SHERIFF'S DEPARTMENT WHEN A WORKER BUMPED A | | KEY SWITCH DURING REMODELING WORK. AT 0046, THE SHERIFF TURNED THE SIRENS | | OFF. AT 0047, THE SHERIFF NOTIFIED THE LICENSEE. | | | | THE VIRGINIA DEPARTMENT OF EMERGENCY SERVICES ISSUED A PRESS RELEASE | | STATING THAT THERE WAS NO ACTUAL EMERGENCY. | | | | THE LICENSEE NOTIFIED STATE AND LOCAL OFFICIALS AND THE NRC RESIDENT | | INSPECTOR AND PLANS TO ISSUE A PRESS RELEASE. | | | | * * * UPDATE AT 1512 ON 04/29/98 BY PAGE KEMP TAKEN BY MACKINNON * * * | | | | AN INVESTIGATION BY LOUISA COUNTY OFFICIALS FOUND THAT THE NORTH ANNA EARLY | | WARNING SYSTEM WAS INADVERTENTLY ACTIVATED BY A PERSON IN THE COMMUNICATION | | CENTER INSTEAD OF BEING ACTIVATED BY A WORKER BUMPING A KEY SWITCH DURING | | REMODELING WORK. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. THE NRC OPERATIONS | | OFFICER NOTIFIED THE R2DO PIERCE SKINNER. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |GENERAL INFORMATION or OTHER | |EVENT NUMBER: 34148 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |LICENSEE: EMCON NORTHWEST, INC, SPOKANE, WA |NOTIFICATION DATE: 04/29/98 | | CITY: SPOKANE REGION: 4 |NOTIFICATION TIME: 07:30 [ET]| | COUNTY: STATE: WA |EVENT DATE: 04/27/98 | |LICENSE#: WN-10309-1 AGREEMENT: Y |EVENT TIME: 06:00[PDT]| | DOCKET: |LAST UPDATE DATE: 04/29/98 | | +-----------------------------+ | |PERSON ORGANIZATION| | |PHIL HARRELL RDO | | |DON COOL, NMSS EO | +------------------------------------------------+RICH BARRETT IRD | |NRC NOTIFIED BY: TERRY FRAZEE, STATE OF WA |FEMA, DOE, USDA, FAX | |HQ OPS OFFICER: DICK JOLLIFFE |HHS, EPA, DOT (NRC) FAX | +------------------------------------------------+ | |EMERGENCY CLASS: NOT APPLICABLE | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------+-----------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - AGREEMENT STATE REPORT - STOLEN TROXLER MOISTURE DENSITY GAUGE - | | | | TERRY FRAZEE, STATE OF WASHINGTON, REPORTED THE FOLLOWING EVENT: | | | | WHEN EMPLOYEES ARRIVED AT WORK AT 0600 PDT ON 04/27/98, THEY DISCOVERED | | THAT A BREAK IN HAD OCCURRED BETWEEN 1200 PDT ON 04/26/98 AND 0600 PDT | | ON 04/27/98 AT THE SPOKANE OFFICE OF EMCON NORTHWEST, INC, A WASHINGTON | | AGREEMENT STATE LICENSEE HEADQUARTERED IN BOTHELL, WA. THE THIEF OPENED | | TWO LOCK BOXES CONTAINING MONEY AND VEHICLE KEYS AND STOLE A PICKUP TRUCK | | THAT WAS PARKED INSIDE THE LOCKED EMCON FACILITY. A TROXLER MOISTURE | | DENSITY GAUGE, MODEL #3440, SERIAL #24382, WITH A 9 mCi Cs-137 AND | | 44 mCi Am-241/Be SOURCE WAS SECURED IN THE BED OF THE TRUCK IN PREPARATION | | FOR THE NEXT DAY'S JOB. THE LICENSEE NOTIFIED THE LOCAL POLICE WHO ARE | | INVESTIGATING THE ROBBERY. THE STATE OF WASHINGTON REFERENCE NUMBER FOR | | THIS REPORT IS WA-98-016. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 34149 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: FITZPATRICK REGION: 1 |NOTIFICATION DATE: 04/29/98 | |UNIT: [1] [ ] [ ] STATE: NY |NOTIFICATION TIME: 16:11 [ET]| |RX TYPE: [1] GE-4 |EVENT DATE: 04/29/98 | +------------------------------------------------+EVENT TIME: 15:44[EDT]| |NRC NOTIFIED BY: ZAREMBA |LAST UPDATE DATE: 04/29/98 | |HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |HAROLD GRAY RDO | |AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | | |NLCO TECH SPEC LCO A/S | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | 24 HOUR TECH SPEC LCO ENTERED ON POSTULATED LOSS OF THE ADS. | | | | SAFETY RELATED DISTRIBUTION PANEL #71ACA3 CIRCUIT #8 FEEDS NON-SAFETY | | RELATED COMPONENTS #02-2FIS-17A, 21A, 23A, AND 26A IN THE DRYWELL. | | A POSTULATED SMALL BREAK LOSS OF COOLANT ACCIDENT AND A RESULTANT SHORT | | CIRCUIT DUE TO A FAILURE OF ONE OF THE NON-SAFETY RELATED COMPONENTS WITH | | THE RANDOM SINGLE FAILURE OF THE CIRCUIT BREAKER PRESUMED COULD COMPROMISE | | THE FUNCTIONALITY OF THE AUTOMATIC DEPRESSURIZATION SYSTEM (ADS). ADS | | CIRCUIT CABLES ARE ROUTED WITH THE NON-SAFETY RELATED COMPONENTS CABLE. | | A SHORT IN THE NON-SAFETY RELATED CABLE COULD DAMAGE THE ADS CABLE. THE | | NON-SAFETY RELATED COMPONENTS PROVIDE ANNUNCIATION FOR THE RECIRCULATION | | PUMP MOTOR COOLERS, COOLING WATER FLOW AND THE RECIRCULATION PUMP SEAL | | LEAKAGE. THE LICENSEE ENTERED 24 HOUR TECH SPEC 3.5.D.2 LIMITING CONDITION | | OF OPERATION (LCO) FOR ADS INOPERABLE. THE LICENSEE WILL OPEN THE BREAKER | | UNTIL A PERMANENT DESIGN CHANGE CAN BE IMPLEMENTED AND EXIT THE LCO. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | | | | * * * UPDATE AT 1727 ON 04/29/98 BY PHIL RUSSELL TAKEN BY MACKINNON * * * | | | | AT 1650, THE LICENSEE EXITED TECH SPEC 3.5.D.2 AFTER OPENING THE ABOVE | | CIRCUIT BREAKER. THE LICENSEE STILL HAS TEMPERATURE AND PRESSURE | | INDICATIONS FOR THE RECIRC PUMPS AND THEY WILL BE READ EVERY TWO HOURS. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. THE NRC OPERATIONS | | OFFICER NOTIFIED THE R1DO HAROLD GRAY. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 34150 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: SAN ONOFRE REGION: 4 |NOTIFICATION DATE: 04/29/98 | |UNIT: [ ] [2] [3] STATE: CA |NOTIFICATION TIME: 17:29 [ET]| |RX TYPE: [1] W-3-LP,[2] CE,[3] CE |EVENT DATE: 04/29/98 | +------------------------------------------------+EVENT TIME: 13:25[PDT]| |NRC NOTIFIED BY: CLAY WILLIAMS |LAST UPDATE DATE: 04/29/98 | |HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |PHIL HARRELL RDO | |AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | | | 2 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | 3 | N Y 100 POWER OPERATION | 100 POWER OPERATION | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | CERTAIN PROCEDURAL STEPS IN THE ABNORMAL OPERATING INSTRUCTION (AOI) FOR | | NATURAL DISASTER/SEVERE WEATHER HAD BEEN INADVERTENTLY OMITTED. | | | | "ON APRIL 29, 1998 AT ABOUT 1325 PDT, SOUTHERN CALIFORNIA EDISON (SCE) | | RECOGNIZED THAT IN MID-1996, CERTAIN PROCEDURAL STEPS HAD BEEN | | INADVERTENTLY OMITTED FROM AN ABNORMAL OPERATING INSTRUCTION (S023-13-3, | | NATURAL DISASTER/SEVERE WEATHER). THESE PROCEDURAL STEPS WERE INTENDED | | TO ENSURE PLANT OPERATORS WOULD ISOLATE NON-SEISMICALLY QUALIFIED PIPING | | CONNECTIONS TO ONE OF TWO CONDENSATE STORAGE TANKS (T-120) FOLLOWING A | | SEISMIC EVENT. THIS WOULD LIMIT POSTULATED POST-SEISMIC EVENT LEAKAGE FROM | | T-120 TO ENSURE ADEQUATE WATER INVENTORY TO COMPLY WITH THE DESIGN BASIS | | WATER VOLUME (200,000 GALLONS) FOR THE TANK. | | | | "SCE BELIEVES THIS OCCURRENCE HAS NO SAFETY SIGNIFICANCE BECAUSE: | | 1) SUFFICIENT WATER IS CONTAINED IN SEISMICALLY QUALIFIED STORAGE TANK | | (T-121) TO ALLOW OPERATORS TO SAFELY SHUT DOWN THE PLANT, AND 2) PLANT | | OPERATORS HAD BEEN TRAINED ON POST-SEISMIC EVENT RESPONSE (MONITOR PLANT | | INDICATIONS AND TAKE APPROPRIATE ACTIONS). | | | | "ALTHOUGH THE AOI OMITTED THE STEPS TO ISOLATE THE NON-SEISMICALLY | | QUALIFIED CONNECTIONS, THE ALARM RESPONSE PROCEDURE DOES CONTAIN THE | | REQUIRED INSTRUCTIONS. IF T-120 BEGAN LEAKING FOLLOWING A SEISMIC EVENT, | | OPERATORS WOULD BE ALERTED TO A FALLING WATER LEVEL BY A NON-SEISMICALLY | | QUALIFIED LEVEL INDICATOR AND ALARM IN THE CONTROL ROOM. SCE HAS INFORMED | | THE CONTROL ROOM OPERATORS OF THIS CONDITION AND IS REVISING THE AOI | | (EXPECTED TO BE COMPLETED WITHIN A FEW HOURS)." | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |FUEL CYCLE FACILITY | |EVENT NUMBER: 34151 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 04/29/98 | | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 17:38 [ET]| |COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 04/29/98 | | 6903 ROCKLEDGE DRIVE |EVENT TIME: 14:30[EDT]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 04/29/98 | | CITY: PIKETON REGION: 3 +-----------------------------+ | COUNTY: PIKE STATE: OH |PERSON ORGANIZATION| |LICENSE#: GDP-2 AGREEMENT: N |ROGER LANKSBURY RDO | | DOCKET: 0707002 |FRED COMBS, NMSS EO | +------------------------------------------------+RICH BARRETT, MGR IRD | |NRC NOTIFIED BY: STEVE MAY | | |HQ OPS OFFICER: JOHN MacKINNON | | +------------------------------------------------+ | |EMERGENCY CLASS: NOT APPLICABLE | | |10 CFR SECTION: | | |NBNL RESPONSE-BULLETIN | | | | | | | | | | | | | | +------------------------------------------------+-----------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | NRC BULLETIN 91-01, 4 HOUR REPORT. | | | | NUCLEAR CRITICALITY SAFETY APPROVAL (NCSA) DOES NOT DOCUMENT THAT DOUBLE | | CONTINGENCY IS MET FOR WET AIR INLEAKAGE AND LUBE OIL INLEAKAGE FOR THE | | EXTENDED RANGE PRODUCT WITHDRAWAL STATION. | | | | NUCLEAR CRITICALITY SAFETY PERSONNEL DISCOVERED THAT THE EXTENDED RANGE | | PRODUCT (ERP) WITHDRAWAL STATION (WITHDRAWS LOW ASSAY LIQUID URANIUM | | HEXAFLUORIDE INTO CYLINDERS) NCSA DOES NOT DOCUMENT THAT DOUBLE CONTINGENCY | | IS MET FOR WET AIR INLEAKAGE AND LUBE OIL INLEAKAGE. NCSA-0326_015.A03 | | WAS WRITTEN TO ADDRESS THIS ISSUE, BUT WAS NEVER APPROVED BY THE PLANT | | OPERATIONS REVIEW COMMITTEE. CONTROLS (MODERATION AND GEOMETRY) WERE | | MAINTAINED THROUGHOUT THIS EVENT. THIS IS ALSO A VIOLATION OF THE PLANT | | TECHNICAL SAFETY REQUIREMENT. THE PLANT SUPERINTENDENT DIRECTED THE ERP | | STATION TO BE PLACED IN STANDBY. THERE WAS NO LOSS OF HAZARD/RADIOACTIVE | | MATERIAL OR RADIOACTIVE/RADIOLOGICAL CONTAMINATION EXPOSURE AS A RESULT OF | | THIS EVENT. | | | | THIS IS A DOCUMENTATION PROBLEM. THE OPERATION DOES IN FACT MEET DOUBLE | | CONTINGENCY, AS DEMONSTRATED IN THE ANALOGOUS NCSA FOR THE LOW ASSAY | | WITHDRAWAL STATION (0333_017.A01). | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 34152 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: NINE MILE POINT REGION: 1 |NOTIFICATION DATE: 04/29/98 | |UNIT: [1] [ ] [ ] STATE: NY |NOTIFICATION TIME: 18:07 [ET]| |RX TYPE: [1] GE-2,[2] GE-5 |EVENT DATE: 04/29/98 | +------------------------------------------------+EVENT TIME: 17:00[EDT]| |NRC NOTIFIED BY: DOUG LeCUYER |LAST UPDATE DATE: 04/29/98 | |HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |HAROLD GRAY RDO | |ADAS 50.72(b)(2)(i) DEG/UNANALYZED COND | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N N 0 COLD SHUTDOWN | 0 COLD SHUTDOWN | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | DAMAGED/MISSING AUXILIARY CONTROL ROOM WALLS AND BEAMS FIRE PROOFING. | | | | THE LICENSEE PERFORMED AN ASSESSMENT OF THE STRUCTURAL FIRE PROTECTION | | MATERIAL IN VARIOUS PLANT LOCATIONS. THE ASSESSMENT FOUND THAT FIRE | | PROOFING ON AUXILIARY CONTROL ROOM WALLS AND BEAMS WAS DAMAGED AND DID NOT | | MEET THE DESIGN CRITERIA OF PROVIDING A FIRE BARRIER RATED FOR THREE HOURS. | | IN ADDITION, A SUPPORT BEAM ADJACENT TO THE AUXILIARY CONTROL ROOM WAS | | FOUND WITH THE FIRE PROOFING MATERIAL MISSING, THUS AFFECTING THE FIRE | | RATING OF THE AUXILIARY CONTROL ROOM WALL. THESE CONDITIONS CONSTITUTE | | NONCONFORMANCES TO THE FIRE PROTECTION PROGRAM WHICH MAY HAVE AFFECTED | | THE ABILITY TO ACHIEVE AND MAINTAIN SAFE PLANT SHUTDOWN. | | | | THE LICENSEE WILL INFORM THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+