U.S. Nuclear Regulatory Commission Operations Center Event Reports For 10/03/95 - 10/04/95 ** EVENT NUMBERS ** 29408 29409 29410 29411 29412 29413 29414 +----------------------------------+ +-----------------------+ |TRANSPORTATION EVENT | |EVENT NUMBER: 29408 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |LICENSEE: DUPONT PHARMACEUTICAL |NOTIFICATION DATE: 10/03/95 | | CITY: VANDALIA REGION: 3 |NOTIFICATION TIME: 04:00 [ET]| | COUNTY: STATE: OH |EVENT DATE: 10/03/95 | |LICENSE#: AGREEMENT: N |EVENT TIME: 01:20[EDT]| | DOCKET: |LAST UPDATE DATE: 10/03/95 | | +-----------------------------+ | |PERSON ORGANIZATION| | |WAYNE KROPP RDO | | |DON COOL, NMSS EO | +------------------------------------------------+ | |NRC NOTIFIED BY: BRIGHT, DOT NRC | | |HQ OPS OFFICER: JOHN MacKINNON | | +------------------------------------------------+ | |EMERGENCY CLASS: NOT APPLICABLE | | |10 CFR SECTION: | | |NINF INFORMATION ONLY | | | | | | | | | | | | | | +------------------------------------------------+-----------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE DOT NATIONAL RESPONSE CENTER (NRC) NOTIFIED THE OPERATIONS CENTER THAT | | EMERY WORLDWIDE HAD A RELEASE OF THALLIUM-201 (USED FOR THYROID TREATMENT). | | | | EMERY WORLDWIDE PROVIDED THE FOLLOWING ADDITIONAL INFORMATION TO THE HOO: | | | | THIS EVENT OCCURRED AT THE EMERY WORLDWIDE FACILITY AT THE DAYTON | | INTERNATIONAL AIRPORT, VANDALIA, OHIO. | | | | THE SHIPPER OF THE MATERIAL WAS A DUPONT RADIOPHARMACY LOCATED IN | | BILLERICA, MASSACHUSETTS. EMERY WORLDWIDE RECEIVED A PACKAGE WITH 6 VIALS | | OF THALLIUM-201 (LIQUID SALT FORM). THE ACTIVITIES OF THE 6 VIALS WERE | | 2.4 GBq, 1.8 GBq, 1.6 GBq, 1.4 GBq, 1.1 GBq, AND 0.9 GBq. EMERY WORLDWIDE | | DID NOT KNOW WHICH VIAL WAS DAMAGED. | | | | ONE OF THE SIX VIALS WAS DAMAGED WHEN A FORK LIFT RAN OVER THE PACKAGE | | CONTAINING THE VIALS. ONE OF THE VIALS BROKE OPEN SPILLING SOME OF ITS | | CONTENTS ONTO THE FLOOR. THE PACKAGE WAS LABELLED RADIOACTIVE MATERIAL NOS | | CLASS 7, UN2982. IT WAS A TYPE "A" PACKAGE "II YELLOW". THE PACKAGE WAS | | BEING SHIPPED TO DUPONT CANADA, INC., LOCATED IN TORONTO, CANADA. | | | | THE BROKEN VIAL AND ITS CONTENTS WERE CLEANED UP AND PLACED IN A SALVAGE | | DRUM. DUPONT PHARMACEUTICAL SAID THAT THE ACTIVITY OF THE THALLIUM-201 WAS | | EXTREMELY LOW AND DID NOT POSE ANY THREAT TO HUMANS. | | | | REGION 3 (B.J. HOLT) SPOKE WITH A REPRESENTATIVE FROM THE EMERY WORLDWIDE | | SHIPPING COMPANY. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 29409 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: FT CALHOUN REGION: 4 |NOTIFICATION DATE: 10/03/95 | |UNIT: [1] [ ] [ ] STATE: NE |NOTIFICATION TIME: 12:40 [ET]| |RX TYPE: [1] CE |EVENT DATE: 10/03/95 | +------------------------------------------------+EVENT TIME: 09:40[CDT]| |NRC NOTIFIED BY: CHARLES A. CARLSON |LAST UPDATE DATE: 10/03/95 | |HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |JOHN PELLET RDO | |APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OFFSITE NOTIFICATION OF AN INADVERTENT SIREN SOUNDING DURING A PRACTICE | | EMERGENCY EXERCISE | | | | THE EMERGENCY NOTIFICATION SYSTEM SIRENS IN HARRISON COUNTY, IOWA, WERE | | INADVERTENTLY ACTUATED DURING A PRACTICE EXERCISE OF THE EMERGENCY PLAN | | WITH PARTICIPATION OF OFFSITE STATE AGENCIES. ALL OF THE INADVERTENTLY | | ACTUATED SIRENS SOUNDED PROPERLY WITH THE EXCEPTION OF TWO. THE CAUSE OF | | THE INADVERTENT ACTUATION HAS NOT YET BEEN DETERMINED. | | | | PER STATION PROCEDURES, THE LICENSEE NOTIFIED THE LOCAL RADIO STATION | | RESPONSIBLE FOR PUBLIC ANNOUNCEMENTS TO ENSURE THAT THE "ACCIDENTAL SIREN | | SOUNDING" ANNOUNCEMENTS WERE MADE. THE LICENSEE ALSO NOTIFIED THE NRC | | RESIDENT INSPECTOR AND THE APPLICABLE STATE AND LOCAL GOVERNMENT AGENCIES. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 29410 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: SUSQUEHANNA REGION: 1 |NOTIFICATION DATE: 10/03/95 | |UNIT: [1] [2] [ ] STATE: PA |NOTIFICATION TIME: 15:28 [ET]| |RX TYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 10/03/95 | +------------------------------------------------+EVENT TIME: 11:00[EDT]| |NRC NOTIFIED BY: DAN BOYLE |LAST UPDATE DATE: 10/03/95 | |HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |JOHN WHITE RDO | |NLTR LICENSEE 24 HR REPORT | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | 2 | N N 0 REFUELING | 0 REFUELING | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LICENSE CONDITION VIOLATION REGARDING THE PERFORMANCE OF HOSE STREAM | | TESTING FOR PENETRATION SEALS | | | | THE LICENSEE'S FIRE PROTECTION REVIEW REPORT REQUIRES THAT PENETRATION | | SEALS BE HOSE STREAM TESTED IN ACCORDANCE WITH ASTM-E-119, AND CONTRARY TO | | THIS COMMITMENT, TESTING WAS PERFORMED IN ACCORDANCE WITH IEEE-634. THE | | LICENSEE HAS EVALUATED THIS AS A VIOLATION OF THE FIRE PROTECTION REVIEW | | REPORT, AND AS SUCH, IT IS A VIOLATION OF A LICENSE CONDITION. | | | | THE LICENSEE'S ENGINEERING EVALUATION CONCLUDED THAT ALL FIRE BARRIERS ARE | | OPERABLE. THE HOSE STREAM TESTING PERFORMED IN ACCORDANCE WITH IEEE-634 | | (AN ACCEPTED INDUSTRY STANDARD) IS SIMILAR TO THE TESTING REQUIREMENTS OF | | ASTM-E-119. ADDITIONALLY, OTHER TEST REPORTS EXIST THAT SUCCESSFULLY | | DOCUMENT ASTM-E-119 HOSE STREAM TESTING FOR SEAL CONFIGURATIONS WITH THE | | SAME MATERIAL AS THE IEEE-634 BASED TEST AND LESSER SEALANT DEPTHS. | | THEREFORE, THE SEALS QUALIFIED UNDER IEEE-634 ARE NOT CONSIDERED BY THE | | LICENSEE TO BE DEGRADED AND ARE CONSIDERED TO BE OPERABLE. | | | | THE LICENSEE NOTIFIED THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |TRANSPORTATION EVENT | |EVENT NUMBER: 29411 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |LICENSEE: ASSOCIATED COURIER |NOTIFICATION DATE: 10/03/95 | | CITY: LEMONT REGION: 3 |NOTIFICATION TIME: 17:36 [ET]| | COUNTY: COOK STATE: IL |EVENT DATE: 10/03/95 | |LICENSE#: AGREEMENT: Y |EVENT TIME: 13:00[CDT]| | DOCKET: |LAST UPDATE DATE: 10/03/95 | | +-----------------------------+ | |PERSON ORGANIZATION| | |WAYNE KROPP RDO | | |JOHN AUSTIN (NMSS) EO | +------------------------------------------------+ | |NRC NOTIFIED BY: SHORES (NAT'L RESP CNTR) |REGGIE JOHNSON DOE | |HQ OPS OFFICER: LEIGH TROCINE | | +------------------------------------------------+ | |EMERGENCY CLASS: NOT APPLICABLE | | |10 CFR SECTION: | | |NTRA TRANSPORTATION EVENT | | | | | | | | | | | | | | +------------------------------------------------+-----------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE NATIONAL RESPONSE CENTER REPORTED THAT A PACKAGE CONTAINING A | | MOLYBDENUM-99/TECHNETIUM-99M GENERATOR FELL OFF THE BACK OF AN ASSOCIATED | | COURIER TRUCK ON THE LEMONT BRIDGE IN LEMONT, ILLINOIS. | | | | AT 13:00 CDT, A PACKAGE CONTAINING AN OLD MOLYBDENUM-99/TECHNETIUM-99M | | GENERATOR FELL OFF THE BACK OF AN ASSOCIATED COURIER TRUCK ON THE LEMONT | | BRIDGE. THIS BRIDGE SPANS THE DES PLAINES RIVER AND THE ILLINOIS AND | | MICHIGAN CANAL, AND IT IS THE MAIN THOROUGHFARE GOING INTO LEMONT, | | ILLINOIS, IN COOK COUNTY. THE PACKAGE WAS OWNED BY AMERSHAM METAPHYSICS | | AND WAS BEING TRANSPORTED FROM MILWAUKEE, WISCONSIN, TO CHICAGO, ILLINOIS. | | (THE SHIPPING PAPERS WERE NOT AVAILABLE.) | | | | AFTER FALLING OUT OF THE TRUCK, THE PACKAGE WAS STRUCK BY SEVERAL VEHICLES | | AND WAS DEMOLISHED. AS A RESULT, THE ROADWAY ON THE BRIDGE WAS | | CONTAMINATED WITH 1.4 GIGABECQUERELS OF MOLYBDENUM-99 (40 MILLICURIES). IT | | BEGAN TO RAIN SHORTLY AFTER THE EVENT, AND SOME OF THE RADIOACTIVE MATERIAL | | WAS SPREAD IN PATCHES. THE RADIOACTIVE MATERIAL STAYED ON THE ROADWAY | | (BOTH LANES) AND DID NOT END UP IN THE WATERWAY. THE LOCAL POLICE | | DEPARTMENT, THE ILLINOIS DEPARTMENT OF NUCLEAR SAFETY, AND THE DEPARTMENT | | OF ENERGY (ARGON NATIONAL LABORATORY) RESPONDED TO THIS EVENT. THE BRIDGE | | WAS SUBSEQUENTLY CLOSED. THERE HAS BEEN NO MEDIA COVERAGE, AND A PRESS | | RELEASE IS NOT PLANNED AT THIS TIME. THERE WERE NO INJURIES ASSOCIATED | | WITH THIS EVENT. (REFER TO THE HOO LOG FOR CONTACT TELEPHONE NUMBERS.) | | | | * * * 18:59 OCTOBER 3, 1995, UPDATE FROM SHORES RECEIVED BY TROCINE * * * | | | | THE BRIDGE WAS DECONTAMINATED AND REOPENED AT 17:30 CDT. | | | | NOTE: THIS NOTIFICATION WAS ALSO RECEIVED FROM THE ILLINOIS DEPARTMENT OF | | NUCLEAR SAFETY (COLLINS) AT 18:31 EDT AND FROM ASSOCIATED COURIERS (SOLDAN) | | AT 19:04 EDT. A CONFERENCE CALL WAS ALSO ESTABLISHED WITH THE ILLINOIS | | DEPARTMENT OF NUCLEAR SAFETY (COLLINS) AND THE REGION 3 AGREEMENT STATES | | LIAISON OFFICER (LYNCH) AT APPROXIMATELY 18:40 EDT. DURING THIS CONFERENCE | | CALL, THE ILLINOIS DEPARTMENT OF NUCLEAR SAFETY (COLLINS) INDICATED THAT | | APPROXIMATELY ONE ACRE OF THE ROADWAY HAD BEEN SURVEYED AND THAT THE HOT | | SPOTS HAD BEEN DECONTAMINATED TO ACCEPTABLE LEVELS WITH SPONGES AND WATER. | | THE CONTAMINATED MATERIAL WAS SUBSEQUENTLY PLACED IN A SHIELDED BUCKET AND | | WAS RETURNED TO AMERSHAM METAPHYSICS. THE REGION 3 AGREEMENT STATES | | LIAISON OFFICER (LYNCH) ALSO STATED THAT HE HAD NOTIFIED THE REGION 3 | | PUBLIC AFFAIRS OFFICER. THE NRC OPERATIONS CENTER NOTIFIED THE R3DO | | (KROPP), NMSS EO (AUSTIN), AND THE DEPARTMENT OF ENERGY (JOHNSON). | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 29412 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: DIABLO CANYON REGION: 4 |NOTIFICATION DATE: 10/03/95 | |UNIT: [1] [ ] [ ] STATE: CA |NOTIFICATION TIME: 19:20 [ET]| |RX TYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 10/03/95 | +------------------------------------------------+EVENT TIME: 15:30[PDT]| |NRC NOTIFIED BY: GLEN GOELVER |LAST UPDATE DATE: 10/03/95 | |HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |JOHN PELLET RDO | |AAAA 50.72 UNSPECIFIED PARAGRAPH |DAVID MATTHEWS (NRR) EO | | |BOB CALDWELL FEMA | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N N 0 REFUELING | 0 REFUELING | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | DISCOVERY THAT AN UNUSUAL EVENT SHOULD HAVE BEEN DECLARED DUE TO THE | | TRANSPORT OF OF A CONTAMINATED INDIVIDUAL TO A LOCAL HOSPITAL | | | | AT 04:50 PDT, AN INDIVIDUAL WORKING IN A POTENTIALLY CONTAMINATED AREA | | SUFFERED FROM RESPIRATORY DISTRESS. BASED ON A SITE MEDICAL EVALUATION, | | THE INDIVIDUAL'S CONDITION WAS CONSIDERED TO BE LIFE THREATENING, AND THE | | INDIVIDUAL WAS SUBSEQUENTLY TRANSPORTED TO A LOCAL HOSPITAL WHILE STILL | | WEARING PROTECTIVE CLOTHING. THE INITIAL SURVEYS CONDUCTED IN THE UNIT 1 | | CONTAINMENT AT 04:55 PDT, THE SITE AMBULANCE AT 05:05 PDT, AND AN OFFSITE | | AMBULANCE AT 05:20 PDT INDICATED THAT THERE WAS NO CONTAMINATION PRESENT. A | | SUBSEQUENT THOROUGH SURVEY PERFORMED AT THE HOSPITAL AT 07:02 PDT INDICATED | | 200 COUNTS PER MINUTE OF FIXED CONTAMINATION ON ONE SHOE COVER. THE | | PROTECTIVE CLOTHING WAS REMOVED AND BAGGED, AND THE INDIVIDUAL WAS FRISKED | | AND FOUND TO BE FREE OF CONTAMINATION. THE BED, GURNEY, AMBULANCE, AND ALL | | OF THE ATTENDANT PERSONNEL WERE ALSO SURVEYED, AND NO CONTAMINATION WAS | | FOUND. THIS WAS INITIALLY REPORTED TO THE SITE AS BEING LESS THAN 100 | | COUNTS PER MINUTE (A CLEAN RELEASE LIMIT). AS A RESULT, NO EMERGENCY OR | | NON-EMERGENCY REPORT WAS MADE. SUBSEQUENT TO THIS, A TECHNICIAN ON THE | | SCENE AT THE HOSPITAL FILLED OUT A RADIATION AND CONTAMINATION SURVEY FORM | | WHICH INDICATED THE 200 COUNT PER MINUTE CONTAMINATION ON ONE SHOE COVER. | | BASED ON THE DOCUMENTED SURVEY, THE CRITERIA FOR MAKING AN EMERGENCY REPORT | | WAS EXCEEDED. THIS LATER WAS DISCOVERED DURING A SITE REVIEW OF THE | | RADIATION AND CONTAMINATION SURVEY FORM AT 15:30 PDT. THE LICENSEE DID NOT | | MAKE A DECLARATION OF EMERGENCY REPORT (NOTICE OF UNUSUAL EVENT) BECAUSE | | THIS CONDITION NO LONGER EXISTED AT THE TIME OF DISCOVERY. THEREFORE, THE | | LICENSEE MADE A ONE HOUR NON-EMERGENCY NOTIFICATION. | | | | THE LICENSEE NOTIFIED THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 29413 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: FARLEY REGION: 2 |NOTIFICATION DATE: 10/03/95 | |UNIT: [1] [2] [ ] STATE: AL |NOTIFICATION TIME: 23:25 [ET]| |RX TYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 10/03/95 | +------------------------------------------------+EVENT TIME: 21:53[CDT]| |NRC NOTIFIED BY: VAUDY HOLLY |LAST UPDATE DATE: 10/03/95 | |HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |MARK LESSER RDO | |AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N N 0 REFUELING | 0 REFUELING | | 2 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | POWER TEMPORARILY LOST TO THE EMERGENCY OPERATING FACILITY (EOF) DURING | | TROUBLESHOOTING WHILE UNIT 1 WAS DEFUELED | | | | DURING PLANNED TROUBLESHOOTING OF SIMILAR EVENTS THAT OCCURRED ON SEPTEMBER | | 28 AND OCTOBER 3, 1995 (REFER TO EVENT NUMBERS 29385 AND 29407.), POWER WAS | | TEMPORARILY LOST TO THE ONSITE EOF. WITH UNIT 1 SHUTDOWN, POWER TO BOTH | | THE 'B' AND 'C' 4160 VOLT BUSSES WAS BEING SUPPLIED FROM EITHER THE | | AUXILIARY TRANSFORMER OR THE STARTUP TRANSFORMER. THIS SYSTEM UTILIZES | | AN AUTOMATIC TRANSFER FEATURE SUCH THAT WHEN ONE SUPPLY BREAKER IS CLOSED, | | THE OTHER SUPPLY BREAKER AUTOMATICALLY OPENS. APPARENTLY, DURING A | | TRANSFER OF THE POWER SUPPLY TO THE 'B' BUS AS PART OF TROUBLESHOOTING | | ACTIVITIES, THE POWER SUPPLY BREAKER TO THE 'C' BUS OPENED, AND POWER TO | | THE EOF WAS LOST AT 21:53 CDT. THE SUPPLY BREAKER WAS RECLOSED, AND POWER | | TO THE 'C' BUS AND EOF WAS RESTORED AT 21:54 CDT. THE LICENSEE IS STILL | | INVESTIGATING THE CAUSE OF THIS PROBLEM. | | | | THE LICENSEE PLANS TO NOTIFY THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 29414 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: CRYSTAL RIVER REGION: 2 |NOTIFICATION DATE: 10/03/95 | |UNIT: [3] [ ] [ ] STATE: FL |NOTIFICATION TIME: 23:46 [ET]| |RX TYPE: [3] B&W-L-LP |EVENT DATE: 10/03/95 | +------------------------------------------------+EVENT TIME: 23:30[EDT]| |NRC NOTIFIED BY: WILSON |LAST UPDATE DATE: 10/03/95 | |HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: UNUSUAL EVENT +-----------------------------+ |10 CFR SECTION: |MARK LESSER RDO | |AAEC 50.72(a)(1)(i) EMERGENCY DECLARED |DAVID MATTHEWS EO | | |ED SIMMERS FEMA | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 3 | N Y 97 POWER OPERATION | 97 POWER OPERATION | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - UNUSUAL EVENT DECLARED DUE TO HURRICANE WARNING FOR FLORIDA WEST COAST - | | | | LICENSEE DECLARED AN UNUSUAL EVENT DUE TO THE ISSUANCE OF A HURRICANE | | WARNING FOR THE WEST COAST OF FLORIDA DUE TO HURRICANE OPAL. | | | | WINDS AT THE SITE ARE PRESENTLY AT 7 MPH. | | | | LICENSEE NOTIFIED STATE AND LOCAL OFFICIALS AND WILL INFORM THE NRC | | RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+