U.S. Nuclear Regulatory Commission Operations Center Event Reports For 07/05/95 - 07/06/95 ** EVENT NUMBERS ** 29024 29025 29026 29027 29028 +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 29024 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: FERMI REGION: 3 |NOTIFICATION DATE: 07/05/95 | |UNIT: [2] [ ] [ ] STATE: MI |NOTIFICATION TIME: 08:31 [ET]| |RX TYPE: [2] GE-4 |EVENT DATE: 07/05/95 | +------------------------------------------------+EVENT TIME: 07:50[EDT]| |NRC NOTIFIED BY: ROBERT GAILLIEZ |LAST UPDATE DATE: 07/05/95 | |HQ OPS OFFICER: DOUG WEAVER +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |BRUCE BURGESS RDO | |DDDD 73.71 UNSPECIFIED PARAGRAPH | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 2 | N Y 95 POWER OPERATION | 95 POWER OPERATION | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SAFEGUARDS SYSTEM DEGRADATION RELATED TO THE PROTECTED AREA BOUNDARY | | | | IMMEDIATE COMPENSATORY MEASURES WERE TAKEN UPON DISCOVERY. THE LICENSEE | | INFORMED THE NRC RESIDENT INSPECTOR. SEE HOO LOG FOR DETAILS | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 29025 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: HATCH REGION: 2 |NOTIFICATION DATE: 07/05/95 | |UNIT: [1] [2] [ ] STATE: GA |NOTIFICATION TIME: 10:39 [ET]| |RX TYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 07/05/95 | +------------------------------------------------+EVENT TIME: 10:00[CDT]| |NRC NOTIFIED BY: JAMES BARNES |LAST UPDATE DATE: 07/05/95 | |HQ OPS OFFICER: DOUG WEAVER +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |THOMAS DECKER RDO | |AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | 2 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE STATE'S NOAA RADIO TRANSMITTER TOWER IS OUT OF SERVICE | | | | THE NOAA TOWER IS USED TO TRANSMIT EMERGENCY INFORMATION TO AREA RESIDENTS. | | PLANT HATCH HAS A SIMILAR TOWER CAPABLE OF TRANSMITTING THIS INFORMATION. | | THE GEORGIA EMERGENCY MANAGEMENT AGENCY HAS GIVEN PLANT HATCH PERMISSION TO | | BROADCAST VIA ITS TOWER IN EMERGENCY SITUATIONS. | | | | STATE AND LOCAL GOVERNMENT AUTHORITIES HAVE BEEN NOTIFIED. THE NOAA TOWER | | SHOULD BE REPAIRED IN TWO DAYS. THE LICENSEE INFORMED THE NRC RESIDENT | | INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 29026 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: FITZPATRICK REGION: 1 |NOTIFICATION DATE: 07/05/95 | |UNIT: [1] [ ] [ ] STATE: NY |NOTIFICATION TIME: 15:37 [ET]| |RX TYPE: [1] GE-4 |EVENT DATE: 07/05/95 | +------------------------------------------------+EVENT TIME: 14:45[EDT]| |NRC NOTIFIED BY: RICHARD SULLIVAN |LAST UPDATE DATE: 07/05/95 | |HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |WILLIAM LAZARUS RDO | |DDDD 73.71 UNSPECIFIED PARAGRAPH | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | DISCOVERY OF UNATTENDED SECURITY/SAFEGUARDS DRAWINGS. | | | | SECURITY/SAFEGUARDS DRAWINGS WERE LEFT UNATTENDED. COMPENSATORY MEASURES | | WERE TAKEN UPON DISCOVERY. REFER TO THE HOO LOG FOR ADDITIONAL DETAILS. | | | | THE LICENSEE NOTIFIED THE RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 29027 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: CRYSTAL RIVER REGION: 2 |NOTIFICATION DATE: 07/05/95 | |UNIT: [3] [ ] [ ] STATE: FL |NOTIFICATION TIME: 16:12 [ET]| |RX TYPE: [3] B&W-L-LP |EVENT DATE: 07/05/95 | +------------------------------------------------+EVENT TIME: 16:00[EDT]| |NRC NOTIFIED BY: IVAN WILSON |LAST UPDATE DATE: 07/05/95 | |HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |THOMAS DECKER RDO | |AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 3 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | CONTROL COMPLEX HABITABILITY ENVELOPE BARRIER SEAL INSTALLED BACKWARDS. | | | | THE LICENSEE DISCOVERED THAT A CONTROL COMPLEX HABITABILITY ENVELOPE | | BARRIER SEAL WAS INSTALLED BACKWARDS. THE LICENSEE'S ENGINEERING STAFF HAS | | DETERMINED THAT THE DOOR WILL STILL FUNCTION AS REQUIRED BUT THAT THE | | REVERSE INSTALLATION MAY BE OUTSIDE THE DESIGN BASIS. THE BARRIER SEAL IN | | QUESTION IS ON A DOOR THAT LEADS FROM THE CONTROL COMPLEX TO THE TURBINE | | DECK, AND IT IS REQUIRED TO SEAL AGAINST TOXIC GASES AND RADIOACTIVE GASES. | | | | THE LICENSEE PLANS TO BUILD A TEMPORARY ENCLOSURE AROUND THE SEAL SO THAT | | THE DOOR CAN BE REMOVED AND THE SEAL REVERSED. THERE IS NO TECHNICAL | | SPECIFICATION ACTION STATEMENT FOR CONTROL COMPLEX HABITABILITY. | | | | THE LICENSEE NOTIFIED THE RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 29028 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: POINT BEACH REGION: 3 |NOTIFICATION DATE: 07/05/95 | |UNIT: [1] [2] [ ] STATE: WI |NOTIFICATION TIME: 22:13 [ET]| |RX TYPE: [1] W-2-LP,[2] W-2-LP |EVENT DATE: 07/05/95 | +------------------------------------------------+EVENT TIME: 20:18[CDT]| |NRC NOTIFIED BY: STEVE JOHNSEN |LAST UPDATE DATE: 07/05/95 | |HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |BRUCE BURGESS RDO | |DDDD 73.71 UNSPECIFIED PARAGRAPH | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | 2 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF CONTROL OF SIGNIFICANT SAFEGUARDS INFORMATION. | | | | SIGNIFICANT SAFEGUARDS INFORMATION WAS LEFT UNATTENDED. COMPENSATORY | | MEASURES WERE TAKEN UPON DISCOVERY. REFER TO THE HOO LOG FOR ADDITIONAL | | DETAILS. | | | | THE LICENSEE WILL INFORM THE RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+