U.S. Nuclear Regulatory Commission Operations Center Event Reports For 06/09/94 - 06/10/94 ** EVENT NUMBERS ** 27225 27372 27373 27374 27375 27376 27377 27378 27379 27380 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 27225 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: HARRIS REGION: 2 |NOTIFICATION DATE: 05/09/94 | |UNIT: [1] [ ] [ ] STATE: NC |NOTIFICATION TIME: 17:07 [ET]| |RX TYPE: [1] W-3-LP |EVENT DATE: 05/09/94 | +------------------------------------------------+EVENT TIME: 15:40[EDT]| |NRC NOTIFIED BY: BRYCE MILLER |LAST UPDATE DATE: 06/09/94 | |HQ OPS OFFICER: RUDY KARSCH +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |MARK LESSER RDO | |ARPS 50.72(b)(2)(ii) RPS ACTUATION | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | M/R N 0 HOT STANDBY | 0 HOT STANDBY | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | MANUAL TRIP DUE TO A DROPPED CONTROL ROD. | | | | THE FOLLOWING FAX WAS RECEIVED: | | "A MANUAL REACTOR TRIP WAS INSERTED DUE TO A DROPPED ROD DURING ROD | | TESTING. THE PLANT WAS IN MODE 3 AT 557 DEGREES F AND 2290 PSIG (RCS | | HYDROSTATIC TEST ALSO IN PROGRESS). EST-724 "SHUTDOWN AND CONTROL ROD DROP | | TEST USING COMPUTER" AND OST-1112 "ROD POSITION INDICATION TEST" WERE BEING | | PERFORMED IN PARALLEL. WHILE WITHDRAWING CONTROL BANK B RODS (8 RODS | | TOTAL), ROD F-4 IN GROUP 1 DROPPED WHEN BANK B REACHED APPROXIMATELY 20 | | STEPS WITHDRAWN. ALL OTHER CONTROL RODS WERE ON THE BOTTOM. ROD F-4 | | DROPPED AT 1540. AN INVESTIGATION ENSUED TO DETERMINE IF THE INDICATION | | WAS DUE TO A ROD POSITION INDICATION PROBLEM. THE ROD WAS DETERMINED TO BE | | DROPPED AND THE REACTOR TRIP BREAKERS WERE MANUALLY OPENED AT 1546. NO | | OBVIOUS CAUSE OF THE ROD DROP WAS FOUND, INVESTIGATION CONTINUING" | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | | | | ***UPDATE AT 08:10 BY PACE TO GOULD*** THIS EVENT IS BEING RETRACTED BY THE | | LICENSEE SINCE A SUBSEQUENT INVESTIGATION AND REPORTABILITY EVALUATION | | DETERMINED THAT THIS CONDITION DID NOT MEET THE IMMEDIATE REPORTABILITY | | REQUIREMENTS OF 10CFR50.72 AND THE 30 DAY WRITTEN FOLLOW-UP(LER) | | REQUIRMENTS. THIS CONTROL ROD INSERTION OCCURRED DURING CONTROL ROD DROP | | TIME TESTING WITH THE REACTOR FULLY SHUTDOWN AND THE REACTOR COOLANT SYSTEM | | BORATED TO COLD S/D CONCENTRATION. THE INSERTION OF THE 7 BANK "B" CONTROL | | RODS THAT WERE WITHDRAWN FOR THE PURPOSE OF DROP TIME TESTING DOES NOT | | CONSTITUTE A RPS ACTUATION AND IS THEREFORE NOT REPORTABLE. THE RI WAS | | INFORMED. (REG2 BARR) | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 27372 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: DUANE ARNOLD REGION: 3 |NOTIFICATION DATE: 06/09/94 | |UNIT: [1] [ ] [ ] STATE: IA |NOTIFICATION TIME: 03:25 [ET]| |RX TYPE: [1] GE-4 |EVENT DATE: 06/09/94 | +------------------------------------------------+EVENT TIME: 01:09[CDT]| |NRC NOTIFIED BY: SCHUSSLER |LAST UPDATE DATE: 06/09/94 | |HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |BRUCE JORGENSEN RDO | |AESF 50.72(b)(2)(ii) ESF ACTUATION | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE PLANT HAD A TRIP OF AN EXCESS FLOW CHECK VALVE DUE TO A LEAK ON A | | PRESSURE DIFFERENTIAL TRANSMITTER. | | | | THIS ESF ACTUATION OCCURRED WHEN THE CONTROL ROD DRIVE DRIVE PRESSURE | | TRANSMITTER STARTED LEAKING IN THE REACTOR BUILDING. THE LEAK WAS ISOLATED, | | THE FLOW CHECK VALVE WAS RESET AND THE REMAINING INSTRUMENTS WERE RETURNED | | TO SERVICE ALL WITHIN 15 MINS. THE RI WAS INFORMED. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 27373 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: SEABROOK REGION: 1 |NOTIFICATION DATE: 06/09/94 | |UNIT: [1] [ ] [ ] STATE: NH |NOTIFICATION TIME: 10:11 [ET]| |RX TYPE: [1] W-4-LP |EVENT DATE: 06/09/94 | +------------------------------------------------+EVENT TIME: 11:00[EDT]| |NRC NOTIFIED BY: MCINTIRE |LAST UPDATE DATE: 06/09/94 | |HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |JIM TRAPP RDO | |APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N N 0 REFUELING | 0 REFUELING | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE LICENSEE IS GOING TO MAKE A PRESS RELEASE ABOUT EXTENDING THEIR CURRENT | | REFUEL OUTAGE BY 4 TO 6 WEEKS DUE TO RCP REPAIRS. | | | | THIS EXTENSION IS BEING MADE DUE TO A BOLT BEING FOUND IN THE BOTTOM OF THE | | REACTOR VESSEL. THE RI ALONG WITH OTHER GOVERNMENT AGENCIES HAVE BEEN | | NOTIFIED. | | | | HOO NOTE: SEE EVENT #27374 | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 27374 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: SEABROOK REGION: 1 |NOTIFICATION DATE: 06/09/94 | |UNIT: [1] [ ] [ ] STATE: NH |NOTIFICATION TIME: 10:11 [ET]| |RX TYPE: [1] W-4-LP |EVENT DATE: 06/07/94 | +------------------------------------------------+EVENT TIME: 15:00[EDT]| |NRC NOTIFIED BY: MCINTIRE |LAST UPDATE DATE: 06/09/94 | |HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |JIM TRAPP RDO | |NLTR LICENSEE 24 HR REPORT | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N N 0 REFUELING | 0 REFUELING | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE LICENSEE IS MAKING THIS 24 HR REPORT IN PURSUANT TO REG GUIDE 1.133 | | SECTION C.6 ABOUT CONFIRMED LOOSE PARTS PROTECTION. | | | | AFTER DETECTING A BOLT IN THE BOTTOM OF THE REACTOR VESSEL, THEY ARE GOING | | TO REPLACE ALL 23 BOLTS ON EACH OF THE 4 REACTOR COOLANT PUMPS. THESE BOLTS | | ARE USED TO SECURE STEEL INSERTS CALLED TURNING VANES(THE VANES DIRECT FLOW | | OF WATER OUT OF THE PUMP DISCHARGE). THEY HAVE ALSO FOUND SOME CAPS THAT | | ARE ASSOCIATED WITH HOLDING THE BOLTS IN PLACE, AND THEY ARE TRYING TO | | RETRIEVE OTHER MISCELLANEOUS PARTS FOR IDENTIFICATION. THE RI WAS INFORMED | | ALONG WITH OTHER GOVERNMENT AGENCIES. A PRESS RELEASE WILL ALSO BE MADE. | | | | HOO NOTE: SEE EVENT #27373. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 27375 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: ARKANSAS NUCLEAR REGION: 4 |NOTIFICATION DATE: 06/09/94 | |UNIT: [ ] [2] [ ] STATE: AR |NOTIFICATION TIME: 13:16 [ET]| |RX TYPE: [1] B&W-L-LP,[2] CE |EVENT DATE: 06/09/94 | +------------------------------------------------+EVENT TIME: 09:45[CDT]| |NRC NOTIFIED BY: DAN CHURCHMAN |LAST UPDATE DATE: 06/09/94 | |HQ OPS OFFICER: RUDY KARSCH +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |GARY SANBORN RDO | |AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP | | |NLCO TECH SPEC LCO A/S | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | | | 2 | N Y 98 POWER OPERATION | 98 POWER OPERATION | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | METEOROLOGICAL DATA TOWER INOPERABLE DUE TO A POSSIBLE LIGHTNING STRIKE. | | | | ALL DATA FROM THE MET TOWER WAS LOST AS A SEVERE WEATHER FRONT MOVED | | THROUGH THE AREA. THE LICENSEE'S EMERGENCY PLAN HAS PROVISION FOR | | ALTERNATE METEOROLOGICAL DATA. THE LICENSEE ENTERED A SEVEN DAY LCO PER | | TECH SPEC SECTION 3.3.3.4. THEY EXPECT TO RESTORE MET TOWER FUNCTIONS | | PRIOR THE EXPIRATION OF THE TIME LIMIT. THE LICENSEE WILL INFORM THE NRC | | RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 27376 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: PERRY REGION: 3 |NOTIFICATION DATE: 06/09/94 | |UNIT: [1] [ ] [ ] STATE: OH |NOTIFICATION TIME: 13:57 [ET]| |RX TYPE: [1] GE-6 |EVENT DATE: 06/09/94 | +------------------------------------------------+EVENT TIME: 10:30[EDT]| |NRC NOTIFIED BY: RODGER STIFFLER |LAST UPDATE DATE: 06/09/94 | |HQ OPS OFFICER: RUDY KARSCH +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |BRUCE JORGENSEN RDO | |AINB 50.72(b)(2)(iii)(B) POT RHR INOP | | |AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N N 0 REFUELING | 0 REFUELING | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | PIPING MODIFICATIONS MADE DURING THE CURRENT OUTAGE CAUSED THE KEEP FILLED | | PRESSURE IN THE EMERGENCY SERVICE WATER SYSTEM TO DROP BELOW THE LOW | | PRESSURE ALARM POINT. | | | | THE PLANT OPERATORS NOTICED AN ESW "A" KEEP FILLED PRESSURE OF 10.5 PSIG, | | WHICH IS BELOW THE CORRECTIVE ACTION POINT OF 13.5 PSIG. THE VALVE LINE UP | | WAS VERIFIED TO BE CORRECT. REVIEW OF THE PIPING SYSTEM CHANGES MADE | | DURING THE OUTAGE INDICATED THAT PRESSURE COULD BE RESTORED IF A BYPASS | | VALVE AROUND THE TEMPERATURE CONTROL VALVE FOR THE TURBINE BUILDING CLOSED | | COOLING WATER HEAT EXCHANGER WAS OPENED. THIS WOULD ALLOW FLOW TO A | | RESTRICTING ORIFICE DOWNSTREAM OF THE VALVE TO PROVIDE SUFFICIENT BACK | | PRESSURE. | | | | AFTER "P41-F390" WAS OPENED TO APPROXIMATELY 70% THE PRESSURE IN ESW B&C | | WERE VERIFIED AS SATISFACTORY, AND ESW "A" KEEP FILLED PRESSURE WAS | | RECORDED AS 14.5 PSIG. THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |HOSPITAL | |EVENT NUMBER: 27377 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |LICENSEE: MIDMICHIGAN REGIONAL MEDICAL CENTER |NOTIFICATION DATE: 06/09/94 | | CITY: MIDLAND REGION: 3 |NOTIFICATION TIME: 15:34 [ET]| | COUNTY: MIDLAND STATE: MI |EVENT DATE: 05/17/94 | |LICENSE#: 21-01549-02 AGREEMENT: N |EVENT TIME: 07:30[EDT]| | DOCKET: |LAST UPDATE DATE: 06/09/94 | | +-----------------------------+ | |PERSON ORGANIZATION| | |BRUCE JORGENSEN RDO | | | | +------------------------------------------------+ | |NRC NOTIFIED BY: LARRY LANGRILL | | |HQ OPS OFFICER: RUDY KARSCH | | +------------------------------------------------+ | |EMERGENCY CLASS: NOT APPLICABLE | | |10 CFR SECTION: | | |LADM 35.33(a) MED MISADMINISTRATION | | | | | | | | | | | | | | +------------------------------------------------+-----------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | MID MICHIGAN REGIONAL MEDICAL CENTER, MIDLAND, MICHIGAN. | | ON JUNE 6, 1994, THE LICENSEE DETERMINED THAT A MEDICAL MISADMINISTRATION | | HAD OCCURRED. ONE OF SIX 38 MILLI Ci CESIUM IMPLANT SOURCES WAS FOUND IN | | THE BED UNDER THE PATIENT'S LEG. THE RADIATION THERAPY STAFF REPLACED THE | | SOURCE IN THE APPLICATOR. THE SKIN DOSE ESTIMATE IS ANYWHERE FROM ZERO TO | | 6000 RAD SHALLOW DOSE. PATIENT FOLLOW UP TO DATE HAS SHOWN NO SKIN | | REACTION. THE THERAPY PROCEDURE HAD A WORST CASE ERROR IN DELIVERY OF THE | | PRESCRIBED DOSE OF 6%. THE LICENSEE HAS REPORTED THIS EVENT TO REGION 3, | | JOHN JONES AND MARK MITCHELL. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 27378 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: FITZPATRICK REGION: 1 |NOTIFICATION DATE: 06/09/94 | |UNIT: [1] [ ] [ ] STATE: NY |NOTIFICATION TIME: 17:00 [ET]| |RX TYPE: [1] GE-4 |EVENT DATE: 06/09/94 | +------------------------------------------------+EVENT TIME: 16:15[EDT]| |NRC NOTIFIED BY: MIKE COLOMB |LAST UPDATE DATE: 06/09/94 | |HQ OPS OFFICER: RUDY KARSCH +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |JIM TRAPP RDO | |AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | | |NLCO TECH SPEC LCO A/S | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | A SINGLE FAILURE OF A RELAY COULD CAUSE FAILURE OF CONTAINMENT ATMOSPHERE | | SAMPLE LINES TO ISOLATE. | | | | WHILE PERFORMING TECH SPEC REVIEW FOR AN AMENDMENT SUBMITTAL, IT WAS | | DETERMINED THAT A SINGLE FAILURE OF A REACTOR VESSEL LOW LEVEL OR HIGH | | DRYWELL PRESSURE RELAY COULD PREVENT ISOLATION OF THE CONTAINMENT | | ATMOSPHERE SAMPLE SYSTEM. THIS INCLUDES 14 LINES BOTH INBOARD AND OUTBOARD | | ISOLATION VALVES. | | | | THE FSAR STATES THAT NO SINGLE FAILURE WILL PREVENT AN ISOLATION FUNCTION. | | THIS CONDITION IS OUTSIDE THE PLANT'S DESIGN BASIS. THE AFFECTED | | PENETRATIONS HAVE BEEN DECLARED INOPERABLE AND REQUIRED LCO ACTIONS ARE | | BEING TAKEN (ISOLATE PENETRATIONS AND TAKE GRAB SAMPLES). THE ADEQUACY OF | | THE DESIGN IS BEING EVALUATED. THE LICENSEE INFORMED THE NRC RESIDENT | | INSPECTOR. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |POWER REACTOR | |EVENT NUMBER: 27379 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |FACILITY: HATCH REGION: 2 |NOTIFICATION DATE: 06/09/94 | |UNIT: [1] [2] [ ] STATE: GA |NOTIFICATION TIME: 17:28 [ET]| |RX TYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 06/09/94 | +------------------------------------------------+EVENT TIME: 16:50[CDT]| |NRC NOTIFIED BY: BARRY COLEMAN |LAST UPDATE DATE: 06/09/94 | |HQ OPS OFFICER: RUDY KARSCH +-----------------------------+ +------------------------------------------------+ NOTIFICATIONS | |EMERGENCY CLASS: NOT APPLICABLE +-----------------------------+ |10 CFR SECTION: |KENNETH BARR RDO | |AESS 50.72(b)(1)(v) EMERGENCY SIREN INOP | | | | | | | | | | | | | | +-----+----------+-------+--------+--------------+--+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | 1 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | 2 | N Y 100 POWER OPERATION | 100 POWER OPERATION | | | | | +-----+---------------------------------------------+--------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE NOAA WEATHER ALERT RADIO SYSTEM USED FOR EVACUATION NOTIFICATION TO THE | | PUBLIC WAS LOST DUE TO SEVERE WEATHER. IT SHOULD BE RESTORED SHORTLY. THE | | LICENSEE HAS NOTIFIED THE GEORGIA EMERGENCY MANAGEMENT AGENCY, THE APPLIND | | COUNTY EMERGENCY MANAGEMENT AGENCY, TOOMVS COUNTY SHERIFF'S OFFICE, AND THE | | REIDSVILLE AND HAZELHURST POLICE DEPARTMENTS. THE LICENSEE WILL INFORM THE | | NRC RESIDENT INSPECTOR. | | | | * * * UPDATE AT 2014 EDT FROM URQUHART TAKEN BY KARSCH * * * | | NOAA RADIO RESTORED AT 1815 EDT. THE LICENSEE INFORMED THE NRC RESIDENT | | INSPECTOR. R2DO (BARR) NOTIFIED. | +------------------------------------------------------------------------------+ +----------------------------------+ +-----------------------+ |OTHER NUCLEAR MATERIAL | |EVENT NUMBER: 27380 | +----------------------------------+ +-----------------------+ +------------------------------------------------+-----------------------------+ |LICENSEE: S.E.G. |NOTIFICATION DATE: 06/09/94 | | CITY: OAK RIDGE REGION: 2 |NOTIFICATION TIME: 18:54 [ET]| | COUNTY: ANDERSON STATE: TN |EVENT DATE: 06/09/94 | |LICENSE#: TN LIC. AGREEMENT: Y |EVENT TIME: 17:20[EDT]| | DOCKET: |LAST UPDATE DATE: 06/09/94 | | +-----------------------------+ | |PERSON ORGANIZATION| | |KENNETH BARR RDO | | | | +------------------------------------------------+ | |NRC NOTIFIED BY: MIKE MOBLEY, TN RAD AGCY. |FRANK INGRAM PA | |HQ OPS OFFICER: RUDY KARSCH | | +------------------------------------------------+ | |EMERGENCY CLASS: NOT APPLICABLE | | |10 CFR SECTION: | | |NINF INFORMATION ONLY | | | | | | | | | | | | | | +------------------------------------------------+-----------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | NOTIFICATION BY THE TENNESSEE RADIATION CONTROL AGENCY OF A FIRE AT A LOW | | LEVEL WASTE PROCESSING FACILITY LICENSED BY THE STATE. THE FIRE WAS IN THE | | "BAG HOUSE", A METAL MELT OPERATION, AT THE FACILITY. THE FIRE LASTED | | ABOUT ONE HOUR. THERE WAS NO INDICATION OF AN AIRBORNE RELEASE, NOR WAS | | THERE ANY PERSONNEL EXPOSURE. THIS WAS A COURTESY NOTIFICATION BY THE | | STATE DUE TO PROBABLE MEDIA COVERAGE. | +------------------------------------------------------------------------------+